[Experimental study of angiography using vascular interventional robot-2(VIR-2)]
- PMID: 22943950
[Experimental study of angiography using vascular interventional robot-2(VIR-2)]
Abstract
Objective: To verify the feasibility and safety of new vascular interventional robot system used in vascular interventional procedures.
Methods: Vascular interventional robot type-2 (VIR-2) included master-slave parts of body propulsion system, image navigation systems and force feedback system, the catheter movement could achieve under automatic control and navigation, force feedback was integrated real-time, followed by in vitro pre-test in vascular model and cerebral angiography in dog. Surgeon controlled vascular interventional robot remotely, the catheter was inserted into the intended target, the catheter positioning error and the operation time would be evaluated.
Results: In vitro pre-test and animal experiment went well; the catheter can enter any branch of vascular. Catheter positioning error was less than 1 mm. The angiography operation in animal was carried out smoothly without complication; the success rate of the operation was 100% and the entire experiment took 26 and 30 minutes, efficiency was slightly improved compared with the VIR-1, and the time what staff exposed to the DSA machine was 0 minute. The resistance of force sensor can be displayed to the operator to provide a security guarantee for the operation. No surgical complications.
Conclusions: VIR-2 is safe and feasible, and can achieve the catheter remote operation and angiography; the master-slave system meets the characteristics of traditional procedure. The three-dimensional image can guide the operation more smoothly; force feedback device provides remote real-time haptic information to provide security for the operation.
Similar articles
-
[Preliminary clinical application of vascular interventional robot].Zhonghua Wai Ke Za Zhi. 2014 Aug;52(8):593-6. Zhonghua Wai Ke Za Zhi. 2014. PMID: 25370759 Chinese.
-
Remote-controlled vascular interventional surgery robot.Int J Med Robot. 2010 Jun;6(2):194-201. doi: 10.1002/rcs.306. Int J Med Robot. 2010. PMID: 20235338
-
A remote-controlled vascular interventional robot: system structure and image guidance.Int J Med Robot. 2013 Jun;9(2):230-9. doi: 10.1002/rcs.1494. Epub 2013 Mar 21. Int J Med Robot. 2013. PMID: 23520192
-
Overview of the vascular interventional robot.Int J Med Robot. 2008 Dec;4(4):289-94. doi: 10.1002/rcs.212. Int J Med Robot. 2008. PMID: 18803340 Review.
-
Design and performance evaluation of collision protection-based safety operation for a haptic robot-assisted catheter operating system.Biomed Microdevices. 2018 Feb 23;20(2):22. doi: 10.1007/s10544-018-0266-8. Biomed Microdevices. 2018. PMID: 29476379 Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources