Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1990 Jan;81(1 Suppl):II38-46.

A comparison of methodologies in detection of the anaerobic threshold

Affiliations
  • PMID: 2295151
Comparative Study

A comparison of methodologies in detection of the anaerobic threshold

K Dickstein et al. Circulation. 1990 Jan.

Abstract

Peak cardiopulmonary exercise performance is readily evaluated. The most appropriate methodology for assessment of submaximal exercise performance, however, is a subject of controversy. Therefore, we assessed the difference between conventional methodologies using standard criteria to estimate the onset of anaerobiosis and compared them with known gas exchange and blood lactate [( La]) concentrations. Oxygen uptake (VO2) was determined at both the gas exchange anaerobic threshold (ATge) and the lactate threshold (LaT) using the following three types of commonly used methodologies in a blinded fashion: 1) conventional techniques based on manual inspection of plots of gas exchange indexes and [La] versus time, 2) computerized linear regression analysis of two-segment model plots for VCO2 versus VO2 and log [La] versus log VO2, and 3) fixed values determining the VO2 at a respiratory exchange ratio (VCO2/VO2) of 1.00 and at an [La] of 2 mmol/l. Respiratory exchange data were collected on a breath-by-breath basis in 30 men with documented myocardial infarction. Simultaneously, arterial blood was sampled for [La] every 20 seconds during maximal exercise on an upright bicycle ergometer programmed for a continuous ramp protocol of 15 W/min. The mean (+/- SD) peak VO2 was 1,463 (+/- 312) ml/min. The mean (+/- SD) VO2 values for each method were as follows: (table; see text) These results indicate that a good positive correlation exists between the gas exchange and lactate data by all three approaches. The chosen fixed values yield the highest threshold detection for both ATge and LaT. Detection was lowest using regression analysis for LaT.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer

Publication types

LinkOut - more resources