Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Jan;97(1):12-7.
doi: 10.1378/chest.97.1.12.

Long-term reproducibility of respiratory gas exchange measurements during exercise in patients with stable cardiac failure

Affiliations

Long-term reproducibility of respiratory gas exchange measurements during exercise in patients with stable cardiac failure

J S Janicki et al. Chest. 1990 Jan.

Abstract

Present-day technology has greatly facilitated the monitoring of respiratory gas exchange in the clinical exercise laboratory. Despite the growing use of these techniques to assess the severity and progression of disease or therapeutic response in patients with heart failure, the long-term reproducibility of oxygen uptake (VO2), carbon dioxide production, minute ventilation, heart rate (HR), and blood pressure at rest and during incremental exercise in such patients, to our knowledge, has not been evaluated. Therefore, the purpose of this study was to quantify the reproducibility of these variables along with exercise duration, maximum VO2 (VO2max) and anaerobic threshold in a group of 16 patients (61 +/- 7 years, 14 male) with chronic, stable cardiac failure of varying severity and etiology who had five or more incremental treadmill exercise tests over a period of time that ranged from 3 to 22 months. For each variable, reproducibility was represented by the coefficient of variation (CVAR). Except for exercise duration, CVAR was not a function of the severity of heart failure and, for all variables, patient-to-patient variation in CVAR was approximately 9 percent. The maximum CVAR for HR, systolic blood pressure, VO2, and VO2max was generally below 10.5 percent and for exercise duration and anaerobic threshold it was less than 12.5 percent. Based on this retrospective analysis, it is concluded that reproducible respiratory gas exchange and HR exercise responses are obtainable over extended periods of time in patients with stable, chronic cardiac failure. Exercise duration, however, is less reproducible in patients with moderate to severe failure.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources