Comparative Study
. 2013 Mar;34(3):518-24.
doi: 10.1007/s00246-012-0486-2. Epub 2012 Sep 6.

Effective radiation dose in computed tomographic angiography of the chest and diagnostic cardiac catheterization in pediatric patients

Affiliations
Comparative Study

Effective radiation dose in computed tomographic angiography of the chest and diagnostic cardiac catheterization in pediatric patients

Timotheus G Watson et al. Pediatr Cardiol. 2013 Mar.

Abstract

Computed tomographic angiography (CTA) and cardiac catheterization are useful adjuncts to echocardiography for delineating cardiovascular anatomy in pediatric patients. These studies require ionizing radiation, and it is paramount to understand the amount of radiation pediatric patients receive when these tests are performed. Modern dosimetry methods facilitate the conversion of radiation doses of varying units into an effective radiation dose. To compare the effective radiation dose between nongated CTA of the chest and diagnostic cardiac catheterization in pediatric patients. This is a retrospective cohort study of patients of patients who underwent either nongated CTA of the chest or diagnostic cardiac catheterization between July 2009 and April 2010. Fifty patients were included in each group as consecutive samples at a single tertiary care center. An effective radiation dose (mSv) was formulated using conversion factors for each group. The median effective dose (ED) for the CTA group was 0.74 mSv compared with 10.8 mSv for the catheterization group (p < 0.0001). The median ED for children <1 year of age in the CTA group was 0.76 mSv compared with 13.4 mSv for the catheterization group (p < 0.0001). Nongated CTA of the chest exposes children to 15 times less radiation than diagnostic cardiac catheterization. Unless hemodynamic data are necessary, CTA of the chest should be considered in lieu of diagnostic cardiac catheterization in patients with known or presumed cardiac disease who need additional imaging beyond echocardiography.

PubMed Disclaimer

References

    1. Eur Radiol. 2011 Mar;21(3):518-29 - PubMed
    1. Congenit Heart Dis. 2006 May;1(3):104-10 - PubMed
    1. AJR Am J Roentgenol. 2010 Jan;194(1):110-8 - PubMed
    1. Pediatr Cardiol. 2011 Apr;32(4):426-32 - PubMed
    1. J Cardiovasc Med (Hagerstown). 2008 Apr;9(4):432 - PubMed

Publication types

MeSH terms