Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Jul-Aug:22 Suppl 8:S46-53.
doi: 10.5301/HIP.2012.9570.

Preformed antibiotic-loaded cement spacers for two-stage revision of infected total hip arthroplasty. Long-term results

Affiliations

Preformed antibiotic-loaded cement spacers for two-stage revision of infected total hip arthroplasty. Long-term results

Carlo L Romanò et al. Hip Int. 2012 Jul-Aug.

Abstract

Two-stage revision is the most widely accepted and performed intervention for chronically infected hip prosthesis and different interim spacers have been proposed. In recent years, antibiotic-loaded preformed spacers have become available on the market. The aim of this retrospective study was to assess the long-term results of two-stage revision with preformed spacers and uncemented hip prosthesis for the treatment of septic hip prosthesis. From 2000 to 2010, 183 consecutive patients underwent two-stage revision of septic hip prosthesis, with a same protocol, including preformed antibiotic-loaded cement spacer and a cementless modular hip revision prosthesis and four to six weeks antibiotic administration. Clinical and radiologic assessment at a minimum follow-up of two years was performed. At a minimum two years follow-up, 10 patients (5.4%) had had an infection recurrence, four (2.2%) an aseptic loosening and four more required partial revision of the modular components of the prosthesis, because of hip instability/dislocation; 21 patients died or were lost to follow-up. Considering all the reasons for revision, survivorship at eleven years was 93.9%. Harris Hip Score improved from 29.1 ± 14.6 pre-operatively to 41.1 ± 15.9 after spacer implant and 81.7 ± 17.6 after hip revision. The main complications after spacer implant included: spacer dislocation (16.4%), intra-operative femoral fractures (2.7%), and thromboembolism (2.1%). Complications after hip revision were: instability/dislocation (4,3%), intra-operative femoral fractures (1.6%), and thromboembolism (3.3%). Two-stage revision of septic hip prosthesis with preformed antibiotic-loaded spacers and cementless hip prosthesis provides satisfactory long-term results, with reduced complications.

PubMed Disclaimer

Similar articles

Cited by

MeSH terms

LinkOut - more resources