Abstract
The transcapillary exchange of a new class of 99mTc-labeled compounds (BATO) were compared to 201Tl in isolated, blood perfused rabbit hearts. During variable blood flow (0.15-2.44 ml/min/g), peak and net extraction (Emax and Enet, respectively), and capillary permeability-surface area product (PScap) were determined with paired indicator-dilution techniques. Serial bolus injections of 201Tl, [111In]albumin, and [99mTc]BATO; chloro[tris(cyclohexanedionedioxime)methyl boronic acid]Tc (SQ30217, n = 8) and a hydroxy-substituted derivative (SQ32014, n = 5) were given to a total of 13 hearts. Mean (+/- s.d.) SQ30217 Emax and Enet were 0.72 +/- 0.09 and 0.55 +/- 0.18, respectively, which were higher than thallium values of 0.57 +/- 0.10 and 0.46 +/- 0.17 (p less than 0.03). Mean SQ30217 PScap was 1.1 +/- 0.4 ml/min/g and was also higher than corresponding thallium determinations (0.7 +/- 0.3; p less than 0.001). SQ32014 Emax, Enet, and PScap were all significantly less than thallium values (p less than 0.001). Thallium and SQ30217 values for Emax and PScap were closely correlated with blood flow (r greater than or equal to 0.73), whereas those for SQ32014 were weakly correlated (r = 0.09). A small clinical pilot study (n = 3) was performed, which showed that SQ32014 was a poor myocardial perfusion agent in man. In summary, transcapillary exchange of SQ30217 is greater than thallium, which in turn, is greater than SQ32014. Therefore, SQ30217 appears to have good clinical potential, but SQ32014 does not.
Similar articles
-
The effect of flow on technetium-99m-teboroxime (SQ30217) and thallium-201 extraction and retention in rabbit heart.J Nucl Med. 1991 Oct;32(10):1979-88. J Nucl Med. 1991. PMID: 1919742
-
Comparison of hypoxia and ouabain effects on the myocardial uptake kinetics of technetium-99m hexakis 2-methoxyisobutyl isonitrile and thallium-201.J Nucl Med. 1989 Sep;30(9):1500-6. J Nucl Med. 1989. PMID: 2527973
-
Myocardial extraction of technetium-99m-[2-(1-methoxybutyl) isonitrile] in the isolated rabbit heart: a myocardial perfusion agent with high extraction and stable retention.J Nucl Med. 1993 Jun;34(6):927-31. J Nucl Med. 1993. PMID: 8509860
-
Physiologic properties of myocardial perfusion tracers.Cardiol Clin. 1994 May;12(2):169-85. Cardiol Clin. 1994. PMID: 8033171 Review.
-
Advances in myocardial perfusion imaging: 99mTc-teboroxime.J Nucl Biol Med (1991). 1992 Apr-Jun;36(2 Suppl):22-8. J Nucl Biol Med (1991). 1992. PMID: 1450239 Review. No abstract available.
Cited by
-
Technetium-labeled myocardial imaging agents.Int J Card Imaging. 1992;8(4):277-87. doi: 10.1007/BF01146027. Int J Card Imaging. 1992. PMID: 1464728 Review.
-
Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.Nucl Med Biol. 2016 Nov;43(11):732-741. doi: 10.1016/j.nucmedbio.2016.05.001. Epub 2016 May 9. Nucl Med Biol. 2016. PMID: 27632344 Free PMC article.
-
Optimal timing for initial and redistribution technetium 99m-N-NOET image acquisition.J Nucl Cardiol. 2000 Mar-Apr;7(2):123-31. doi: 10.1016/s1071-3581(00)90032-1. J Nucl Cardiol. 2000. PMID: 10796001
-
Myocardial technetium 99m-labeled teboroxime clearance derived from canine scans differentiates severity of stenosis after dipyridamole.J Nucl Cardiol. 1994 Jul-Aug;1(4):338-50. doi: 10.1007/BF02939955. J Nucl Cardiol. 1994. PMID: 9420717
-
Myocardial uptake of thallium 201 and technetium 99m-labeled sestamibi after ischemia and reperfusion: comparison by quantitative dual-tracer autoradiography in rabbits.J Nucl Cardiol. 1994 Jul-Aug;1(4):351-64. doi: 10.1007/BF02939956. J Nucl Cardiol. 1994. PMID: 9420718
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources