Three-dimensional measurement method of arthritic glenoid cavity morphology: feasibility and reproducibility
- PMID: 22964089
- DOI: 10.1016/j.otsr.2012.06.007
Three-dimensional measurement method of arthritic glenoid cavity morphology: feasibility and reproducibility
Abstract
Introduction: Glenoid component loosening is the main complication of total shoulder arthroplasty. Better knowledge of the arthritic glenoid cavity anatomy can help in developing new implants and techniques. The goal of this study was to describe and validate the reproducibility of a CT scan-based, 3D measurement method used to describe various parameters characterizing arthritic glenoid cavity morphology.
Materials and methods: Twelve CT scans and 29 CT arthrogram were evaluated. These scans were taken from 41 patients with glenohumeral osteoarthritis who received an anatomical shoulder prosthesis. A 3D reconstruction of the scapula was performed based on the DICOM files. Following the 3D volume acquisition, points on the glenoid articular surface were manually extracted by three observers, each one three times, allowing one week between readings, to determine the inter- and intra-observer reproducibility. The intraclass correlation coefficient (ICC) was calculated on five 3D parameters that were automatically calculated: glenoïd height, glenoid width, height at maximum width glenoid version and radius of the articular surface best-fit sphere.
Results: The intra-observer and inter-observer ICC were 0.91 to 0.99, and 0.95 to 0.99, respectively.
Discussion: This study is the first to report on a reproducible 3D measurement method, based on CT scans, for the arthritic glenoid cavity, which derives the joint radius of curvature among other morphology parameters. These 3D measurements are advantageous because they are free of problems related to patient positioning in the CT scanner and to the choice of slices, which limits the accuracy of measurements made on slices from 2D CT scans. Three-dimensional methodology similar to ours has been validated on healthy glenoids.
Conclusion: This study confirms the reliability and good reproducibility of our method, which allows us to extend this method to a larger patient cohort and adapt this automated technology to preoperative planning software.
Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Similar articles
-
Accuracy of CT-based measurements of glenoid version for total shoulder arthroplasty.J Shoulder Elbow Surg. 2010 Mar;19(2):166-71. doi: 10.1016/j.jse.2009.08.009. Epub 2009 Dec 2. J Shoulder Elbow Surg. 2010. PMID: 19959378
-
A 2-dimensional glenoid vault method for measuring glenoid version on computed tomography.J Shoulder Elbow Surg. 2012 Mar;21(3):329-35. doi: 10.1016/j.jse.2011.04.006. Epub 2011 Jul 22. J Shoulder Elbow Surg. 2012. PMID: 21782473
-
The influence of three-dimensional planning on decision-making in total shoulder arthroplasty.J Shoulder Elbow Surg. 2017 Aug;26(8):1477-1483. doi: 10.1016/j.jse.2017.01.006. Epub 2017 Feb 2. J Shoulder Elbow Surg. 2017. PMID: 28162884
-
How to Measure Glenoid Bone Stock and Version and Why It Is Important: A Practical Guide.Radiographics. 2020 Oct;40(6):1671-1683. doi: 10.1148/rg.2020200008. Radiographics. 2020. PMID: 33001780 Review.
-
Inconsistencies in measuring glenoid version in shoulder arthroplasty: a systematic review.J Shoulder Elbow Surg. 2025 Feb;34(2):639-649. doi: 10.1016/j.jse.2024.08.020. Epub 2024 Oct 9. J Shoulder Elbow Surg. 2025. PMID: 39389450
Cited by
-
A computed tomography analysis of three-dimensional glenoid orientation modified by glenoid torsion.JSES Open Access. 2018 Sep 21;2(4):194-199. doi: 10.1016/j.jses.2018.07.002. eCollection 2018 Dec. JSES Open Access. 2018. PMID: 30675594 Free PMC article.
-
Axillary view: arthritic glenohumeral anatomy and changes after ream and run.Clin Orthop Relat Res. 2014 Mar;472(3):894-902. doi: 10.1007/s11999-013-3327-6. Epub 2013 Oct 18. Clin Orthop Relat Res. 2014. PMID: 24136806 Free PMC article.
-
Glenoid Inclination: Choosing the Transverse Axis Is Critical-A 3D Automated versus Manually Measured Study.J Clin Med. 2022 Oct 13;11(20):6050. doi: 10.3390/jcm11206050. J Clin Med. 2022. PMID: 36294372 Free PMC article.
-
Reliability of measurements performed on two dimensional and three dimensional computed tomography in glenoid assessment for instability.Int Orthop. 2016 Dec;40(12):2581-2588. doi: 10.1007/s00264-016-3253-9. Epub 2016 Aug 5. Int Orthop. 2016. PMID: 27492723
-
Is the Walch B3 glenoid significantly worse than the B2?Shoulder Elbow. 2018 Oct;10(4):256-261. doi: 10.1177/1758573217724111. Epub 2017 Aug 13. Shoulder Elbow. 2018. PMID: 30214491 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources