. 2012 Nov;56(6):551-8.
doi: 10.1007/s10384-012-0180-1. Epub 2012 Sep 13.

Hong's grading for evaluating anterior chamber angle width

Affiliations

Hong's grading for evaluating anterior chamber angle width

Seok Hwan Kim et al. Jpn J Ophthalmol. 2012 Nov.

Abstract

Purpose: To compare Hong's grading method with anterior segment optical coherence tomography (AS-OCT), gonioscopy, and the dark-room prone-position test (DRPT) for evaluating anterior chamber width.

Methods: The anterior chamber angle was graded using Hong's grading method, and Hong's angle width was calculated from the arctangent of Hong's grades. The correlation between Hong's angle width and AS-OCT parameters was analyzed. The area under the receiver operating characteristic curve (AUC) for Hong's grading method when discriminating between narrow and open angles as determined by gonioscopy was calculated. Correlation analysis was performed between Hong's angle width and intraocular pressure (IOP) changes determined by DRPT.

Results: A total of 60 subjects were enrolled. Of these subjects, 53.5 % had a narrow angle. Hong's angle width correlated significantly with the AS-OCT parameters (r = 0.562-0.719, P < 0.01). A Bland-Altman plot showed relatively good agreement between Hong's angle width and the angle width obtained by AS-OCT. The ability of Hong's grading method to discriminate between open and narrow angles was good (AUC = 0.868, 95 % CI 0.756-0.942). A significant linear correlation was found between Hong's angle width and IOP change determined by DRPT (r = -0.761, P < 0.01).

Conclusions: Hong's grading method is useful for detecting narrow angles. Hong's grading correlated well with AS-OCT parameters and DRPT.

PubMed Disclaimer

Comment in

References

    1. Arch Ophthalmol. 1972 May;87(5):493-6 - PubMed
    1. Korean J Ophthalmol. 2007 Sep;21(3):151-4 - PubMed
    1. Arch Ophthalmol. 2005 Aug;123(8):1053-9 - PubMed
    1. Surv Ophthalmol. 2008 May-Jun;53(3):250-73 - PubMed
    1. J Cataract Refract Surg. 2007 May;33(5):837-40 - PubMed

Publication types

MeSH terms

LinkOut - more resources