Comparative Study
. 2012 Oct 30;26(20):2431-42.
doi: 10.1002/rcm.6359.

Comparison of electrospray ionisation, atmospheric pressure chemical ionisation and atmospheric pressure photoionisation for the identification of metabolites from labile artemisinin-based anti-malarial drugs using a QTRAP® mass spectrometer

Affiliations
Comparative Study

Comparison of electrospray ionisation, atmospheric pressure chemical ionisation and atmospheric pressure photoionisation for the identification of metabolites from labile artemisinin-based anti-malarial drugs using a QTRAP® mass spectrometer

Stefan Louw et al. Rapid Commun Mass Spectrom. .

Abstract

Rationale: Artemisinin-based drugs and their metabolites are prone to in-source fragmentation under atmospheric pressure ionisation mass spectrometry (API-MS) conditions. To facilitate correct and efficient identification of all possible drug metabolites using full scan MS analyzer methods, stable [M + NH(4) ](+) ions should be produced in the MS source.

Methods: Using a high-performance liquid chromatography (HPLC) hybrid triple quadrupole linear ion trap MS system, electrospray ionisation (ESI), atmospheric pressure chemical ionisation (APCI) and atmospheric pressure photoionisation (APPI) methods were developed for the detection of [M + NH(4) ](+) ions of the test compounds dihydroartemisinin, artemisinin, artemether and artesunic acid. The optimised methods employed ammonium formate buffered HPLC mobile phase in combination with moderate source temperatures (100-200 °C) and showed satisfactorily reduced in-source fragmentation.

Results: With a full scan MS analyser method for the detection of the in vitro metabolites of the test compounds, the respective performance of the ESI and APCI methods was found to be comparable. ESI generally resulted in less in-source fragmentation. Incorrect assignment of metabolites resulted from strong in-source fragmentation of artemether using the APPI method. The most number of metabolites could be detected using ESI in combination with a selective MS analyser method.

Conclusions: ESI and APCI full scan methods proved to be capable of detecting any drug metabolites present in reasonable concentrations, and are useful when employed in addition to selective scan methods that target low level expected metabolites. APPI can be a valuable alternative for detecting expected metabolites due to good signal-to-noise (S/N) ratio.