Mechanisms and prediction of aortic regurgitation after TAVI
- PMID: 22995107
- DOI: 10.4244/EIJV8SQA5
Mechanisms and prediction of aortic regurgitation after TAVI
Abstract
It has been demonstrated that moderate to severe paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) procedures are related to impaired long-term prognosis. Anatomical and procedural factors influence the frequency and severity of PVL. Anatomical predictors of this complication are: annulus dimensions and shape, calcium distribution, angle between the ascending aorta axis and the left ventricular outflow tract (LVOT-AO). Procedural predictors: prosthesis-size-annulus mismatch, valve depth deployment and the acquired experience of the centre. An effort has to be made to optimise valve sizing and deployment.
Similar articles
-
Prognostic impact of aortic regurgitation after transcatheter aortic valve implantation.EuroIntervention. 2012 Sep;8 Suppl Q:Q31-3. doi: 10.4244/EIJV8SQA7. EuroIntervention. 2012. PMID: 22995109 Review.
-
Imaging and quantification of aortic regurgitation after TAVI.EuroIntervention. 2012 Sep;8 Suppl Q:Q21-30. doi: 10.4244/EIJV8SQA6. EuroIntervention. 2012. PMID: 22995108 Review.
-
Treatment and prevention of aortic regurgitation after transcatheter aortic valve implantation.EuroIntervention. 2012 Sep;8 Suppl Q:Q34-40. doi: 10.4244/EIJV8SQA8. EuroIntervention. 2012. PMID: 22995110 Review.
-
Paravalvular regurgitation after transcatheter aortic valve replacement: diagnosis, clinical outcome, preventive and therapeutic strategies.Cardiovasc Revasc Med. 2013 May-Jun;14(3):174-81. doi: 10.1016/j.carrev.2013.02.003. Cardiovasc Revasc Med. 2013. PMID: 23773501 Review.
-
Prediction of paravalvular leakage after transcatheter aortic valve implantation.Int J Cardiovasc Imaging. 2015 Oct;31(7):1461-8. doi: 10.1007/s10554-015-0703-1. Epub 2015 Jul 18. Int J Cardiovasc Imaging. 2015. PMID: 26187523 Free PMC article.
Cited by
-
Transcatheter aortic valve implantation.F1000Prime Rep. 2014 Oct 1;6:92. doi: 10.12703/P6-92. eCollection 2014. F1000Prime Rep. 2014. PMID: 25374670 Free PMC article. Review.
-
Early versus newer generation transcatheter heart valves for transcatheter aortic valve implantation: Echocardiographic and hemodynamic evaluation of an all-comers study cohort using the dimensionless aortic regurgitation index (AR-index).PLoS One. 2019 May 31;14(5):e0217544. doi: 10.1371/journal.pone.0217544. eCollection 2019. PLoS One. 2019. PMID: 31150455 Free PMC article.
-
A Retrospective Analysis Assessing Paravalvular Leak and Pacemaker Implantation Using TEE and Non-Contrast CT for CKD Patients Compared With CT Angiography for Annular Sizing Pre-TAVR.Health Sci Rep. 2025 May 22;8(5):e70847. doi: 10.1002/hsr2.70847. eCollection 2025 May. Health Sci Rep. 2025. PMID: 40415983 Free PMC article.
-
Prognostic value of the ratio between prosthesis area and indexed annulus area measured by MultiSlice-CT for transcatheter aortic valve implantation procedures.J Geriatr Cardiol. 2016 Sep;13(6):483-8. doi: 10.11909/j.issn.1671-5411.2016.06.004. J Geriatr Cardiol. 2016. PMID: 27582762 Free PMC article.
-
Balloon-expanding stent and delivery system for transcatheter aortic valve implantation: An animal study.Chronic Dis Transl Med. 2015 Jul 4;1(2):73-80. doi: 10.1016/j.cdtm.2015.06.005. eCollection 2015 Jun. Chronic Dis Transl Med. 2015. PMID: 29062990 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources