Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Sep;5(9):966-73.
doi: 10.1016/j.jcin.2012.06.010.

Coronary endothelial dysfunction distal to stent of first-generation drug-eluting stents

Affiliations
Free article

Coronary endothelial dysfunction distal to stent of first-generation drug-eluting stents

Yoshiaki Mitsutake et al. JACC Cardiovasc Interv. 2012 Sep.
Free article

Abstract

Objectives: This study sought to evaluate the relationship between coronary endothelial function and neointimal coverage after drug-eluting stent (DES) implantation.

Background: The mechanisms of endothelial dysfunction after DES implantation remain to be fully elucidated. We hypothesized that poor neointimal coverage after DES implantation may be associated with endothelial dysfunction distal to the stent site.

Methods: Sixty-six stable angina patients treated with a first-generation DES were enrolled. At 9-month follow-up, coronary endothelial function was evaluated with intracoronary infusion of incremental doses of acetylcholine (10(-8), 10(-7), and 10(-6) mol/l) and nitroglycerin (200 μg). Vascular responses at the segments proximal and distal to the stent site were angiographically and quantitatively measured. At the same time, the degree of neointimal coverage was evaluated using coronary angioscopy and classified into 4 grades: 0 (no coverage) to 3 (full coverage).

Results: We divided the subjects into poor-coverage (grades 0 to 1, n = 33) and good-coverage (grades 2 to 3, n = 33) groups. Acetylcholine induced dose-dependent coronary vasoconstrictions in both groups. At the segment distal to the stent, the magnitude of vasoconstriction to acetylcholine in the poor-coverage group was significantly greater than in the good-coverage group (p < 0.001), whereas vasomotor responses proximal to the stent and vasodilation by nitroglycerine were similar between the 2 groups.

Conclusions: Coronary endothelial dysfunction distal to the stent was associated with poor neointimal coverage after DES implantation.

PubMed Disclaimer

MeSH terms

LinkOut - more resources