. 2012 Dec;19(6):1135-45.
doi: 10.1007/s12350-012-9621-y. Epub 2012 Sep 21.

Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation

Affiliations

Accuracy of low-dose rubidium-82 myocardial perfusion imaging for detection of coronary artery disease using 3D PET and normal database interpretation

Tyler Kaster et al. J Nucl Cardiol. 2012 Dec.

Abstract

Background: Our aim was to develop a normal database to be used for quantification of myocardial perfusion and diagnosis of "obstructive coronary artery disease" (CAD) using low-dose rubidium-82 three-dimensional (3D) positron emission tomography (PET)-CT.

Methods: From a record of 1,501 patients, 77 were identified as having low-likelihood (LLK) of CAD. Forty LLK patients were used to construct a normal database using 4DM-PET, the remainder used for validation of normalcy. A group of 70 patients with CAD who had invasive coronary angiography and PET-CT were used to evaluate the accuracy of the database for detecting CAD using the sum-stress-score. The effect of clinical exclusion criteria and the inclusion of LLK patients were evaluated.

Results: The normal database for CAD detection had a normalcy rate of 95%. Sensitivity was 100% for detecting patients with either 50% or 70% stenosis. Optimal specificity was 87% for either 50% or 70% stenosis. For localizing disease at 50% stenosis in the left anterior descending, left circumflex, and right coronary artery, sensitivity ranged from 59% to 68%, while specificity was maintained at 87-89%. Similarly, at 70% stenosis, sensitivity ranged from 64% to 79%, and specificity from 87% to 91%.

Conclusions: A normal database containing the relative perfusion scores of patients with LLK of CAD can be used to accurately diagnose obstructive coronary disease using low-dose Rb-82 with 3D PET-CT imaging.

PubMed Disclaimer

Comment in

  • Low-dose 3D (82)Rb PET.
    Slomka PJ, Berman DS, Germano G. Slomka PJ, et al. J Nucl Cardiol. 2012 Dec;19(6):1110-2. doi: 10.1007/s12350-012-9637-3. J Nucl Cardiol. 2012. PMID: 23129187 No abstract available.

Similar articles

Cited by

References

    1. J Nucl Cardiol. 2010 Aug;17(4):600-16 - PubMed
    1. Phys Med Biol. 2009 May 21;54(10):3161-71 - PubMed
    1. J Nucl Med. 1994 Apr;35(4):609-18 - PubMed
    1. J Am Coll Cardiol. 2011 Aug 9;58(7):740-8 - PubMed
    1. Phys Med Biol. 2007 Feb 7;52(3):659-73 - PubMed

Publication types

Substances