Outcomes of instrumented fusion in the pediatric cervical spine
- PMID: 22998404
- DOI: 10.3171/2012.8.SPINE12770
Outcomes of instrumented fusion in the pediatric cervical spine
Abstract
Object: The most common cause of cervical spine arthrodesis in the pediatric population is instability related to congenital or traumatic pathology. Instrumenting the cervical spine can be challenging given smaller anatomical structures, less ossified bone, and future growth potential and development. Studies in adult patients have suggested that using screw constructs results in improved outcomes with lower rates of instrumentation failure. However, the pediatric literature is limited to small retrospective series. Based on a review of the literature and their own patient series, the authors report that instrumenting the pediatric cervical spine with screw constructs may be safer and more effective than using wiring techniques.
Methods: The authors reviewed the existing pediatric cervical spine arthrodesis literature and contributed 31 of their own cases from September 1, 2007, to January 1, 2011. They reviewed 204 abstracts from January 1, 1966, to December 31, 2010, and 80 manuscripts with 883 total patients were included in the review. They recorded demographic, radiographic, and outcomes data-as well as surgical details-with a focus on fusion rates and complications. Patients were then grouped into categories based upon the procedure performed: 1) patients who underwent fusions bridging the occipitocervical junction and 2) patients who underwent fusion of the cervical spine that did not include the occiput, thus including atlantoaxial and subaxial fusions. Patients were further subdivided according to the type of instrumentation used-some had posterior cervical fusion with wiring (with or without rod implantation); others had posterior cervical fusion with screws.
Results: The entire series comprised 914 patients with a mean age of 8.30 years. Congenital abnormalities were encountered most often (in 55% of cases), and patients had a mean follow-up of 32.5 months. From the entire cohort, 242 patients (26%) experienced postsurgical complications, and 50 patients (5%) had multiple complications. The overall fusion rate was 94.4%. For occipitocervical fusions (N = 285), both screw and wiring groups had very high fusion rates (99% and 95%, respectively, p = 0.08). However, wiring was associated with a higher complication rate. From a sample of 252 patients, 14% of those treated with screw instrumentation had complications, compared with 50% of patients treated with wiring (p < 0.05). In cervical fusions not involving the occipitocervical junction (N = 181), screw constructs had a 99% fusion rate, whereas wire instrumentation only had an 83% fusion rate (p < 0.05). Similarly, patients who underwent screw fixation had a lower complication profile (15%) when compared with those treated with wiring constructs (54%, p < 0.05).
Conclusions: The results of this study are limited by variations in construct design, use of orthoses, follow-up duration, and newer adjuvant products promoting fusions. However, a literature review and the authors' own series of pediatric cases suggest that instrumentation of the cervical spine in children may be safer and more efficacious using screw constructs rather than wiring techniques.
Similar articles
-
Screw fixation of the upper cervical spine in the pediatric population. Clinical article.J Neurosurg Pediatr. 2009 Jun;3(6):529-33. doi: 10.3171/2009.2.PEDS08149. J Neurosurg Pediatr. 2009. PMID: 19485741
-
Fixation with C-2 laminar screws in occipitocervical or C1-2 constructs in children 5 years of age or younger: a series of 18 patients.J Neurosurg Pediatr. 2014 Jul;14(1):87-93. doi: 10.3171/2014.3.PEDS13626. Epub 2014 May 2. J Neurosurg Pediatr. 2014. PMID: 24784980
-
Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques.J Neurosurg Spine. 2008 Mar;8(3):222-9. doi: 10.3171/SPI/2008/8/3/222. J Neurosurg Spine. 2008. PMID: 18312073 Clinical Trial.
-
Characterizing pediatric cervical fusion in the modern era: indications, complications, and fusion rates.J Neurosurg Pediatr. 2024 Nov 29;35(3):304-313. doi: 10.3171/2024.8.PEDS24122. Print 2025 Mar 1. J Neurosurg Pediatr. 2024. PMID: 39612483
-
Craniocervical fusions in children.J Neurosurg Pediatr. 2012 Jun;9(6):573-85. doi: 10.3171/2012.2.PEDS11371. J Neurosurg Pediatr. 2012. PMID: 22656246 Review.
Cited by
-
Periosteal turndown flap for posterior occipitocervical fusion: a technique review.Eur Spine J. 2017 Sep;26(9):2303-2307. doi: 10.1007/s00586-017-5085-8. Epub 2017 May 2. Eur Spine J. 2017. PMID: 28466094
-
Bone morphogenetic protein in pediatric spine fusion surgery.J Spine Surg. 2016 Mar;2(1):9-12. doi: 10.21037/jss.2016.01.06. J Spine Surg. 2016. PMID: 27683689 Free PMC article. Review.
-
Nonmetallic posterior monosegmental cervical fusion of a dislocated C6/7 fracture in a 4-year-old girl : A case report.Orthopade. 2019 May;48(5):433-439. doi: 10.1007/s00132-019-03714-9. Orthopade. 2019. PMID: 30887057 English.
-
Chiari malformation type I and basilar invagination originating from atlantoaxial instability: a literature review and critical analysis.Acta Neurochir (Wien). 2020 Jul;162(7):1553-1563. doi: 10.1007/s00701-020-04429-z. Epub 2020 Jun 6. Acta Neurochir (Wien). 2020. PMID: 32504118 Free PMC article. Review.
-
Posterior cervical-thoracic spinal fixation using mandibular instrumentation to treat acute cervical spine traumatic instability in the young pediatric population.Spinal Cord Ser Cases. 2025 Jul 14;11(1):18. doi: 10.1038/s41394-025-00715-z. Spinal Cord Ser Cases. 2025. PMID: 40659622
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical