Refinements in microinstrumentation for vitreous surgery
- PMID: 2301535
- DOI: 10.1016/s0002-9394(14)75990-2
Refinements in microinstrumentation for vitreous surgery
Abstract
We developed a series of 25-gauge (0.5 mm) microinstruments for vitreous surgery, including a 25-gauge vitreous cutter, 25-gauge microscissors for limited reuse, and a vitreous membrane dissector. Clinical experience with these instruments in more than 20 cases of advanced proliferative vitreoretinopathy, retinopathy of prematurity, and diabetic retinopathy indicates that these instruments facilitate delicate vitreoretinal dissections, particularly in the vitreous base and when fibrovascular tissues are closely adherent to the retina. Because of their smaller size, the microinstruments are more precise in their cutting capabilities than other instruments.
Similar articles
-
A 27-gauge instrument system for transconjunctival sutureless microincision vitrectomy surgery.Ophthalmology. 2010 Jan;117(1):93-102.e2. doi: 10.1016/j.ophtha.2009.06.043. Epub 2009 Oct 31. Ophthalmology. 2010. PMID: 19880185
-
A 27-gauge sharp-tip short-shaft pneumatic vitreous cutter for transconjunctival sutureless vitreous biopsy.Retina. 2011 Feb;31(2):419-21. doi: 10.1097/IAE.0b013e3182083df8. Retina. 2011. PMID: 21263286 No abstract available.
-
Vitreoretinal and anterior segment surgery through the pars plana: part I.Ann Ophthalmol. 1976 Nov;8(11):1353-81. Ann Ophthalmol. 1976. PMID: 793492
-
[Vitreous surgery for intraocular proliferative disorders].Nippon Ganka Gakkai Zasshi. 1991 May;95(5):405-20. Nippon Ganka Gakkai Zasshi. 1991. PMID: 1872211 Review. Japanese.
-
Management of proliferative diabetic retinopathy.Compr Ophthalmol Update. 2007 Sep-Oct;8(5):245-56. Compr Ophthalmol Update. 2007. PMID: 18201511 Review.
Cited by
-
[Long-term results after pars plana vitrectomy with 25 gauge technique].Ophthalmologe. 2008 May;105(5):445-51. doi: 10.1007/s00347-007-1629-3. Ophthalmologe. 2008. PMID: 17912531 German.
-
Hypersonic vitrectomy in intraoperative posterior capsular rupture with retained nuclear fragments.Indian J Ophthalmol. 2023 Feb;71(2):643-647. doi: 10.4103/ijo.IJO_1199_22. Indian J Ophthalmol. 2023. PMID: 36727378 Free PMC article.
-
Sutureless vitrectomy.Indian J Ophthalmol. 2008 Nov-Dec;56(6):453-8. doi: 10.4103/0301-4738.43364. Indian J Ophthalmol. 2008. PMID: 18974514 Free PMC article. Review.
-
Surgical outcomes of 23-gauge vitrectomy for the management of lens fragments dropped into the vitreous cavity during cataract surgery.Saudi J Ophthalmol. 2014 Oct;28(4):253-6. doi: 10.1016/j.sjopt.2014.01.001. Epub 2014 Feb 3. Saudi J Ophthalmol. 2014. PMID: 25473339 Free PMC article.
-
Pars plana vitrectomy for the repair of primary, inferior rhegmatogenous retinal detachment associated to inferior breaks. A comparison of a 25-gauge versus a 20-gauge system.Graefes Arch Clin Exp Ophthalmol. 2013 Feb;251(2):485-90. doi: 10.1007/s00417-012-2059-8. Epub 2012 May 17. Graefes Arch Clin Exp Ophthalmol. 2013. PMID: 22588289 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources