The Mammotome biopsy system is an effective treatment strategy for breast abscess
- PMID: 23036601
- DOI: 10.1016/j.amjsurg.2012.05.012
The Mammotome biopsy system is an effective treatment strategy for breast abscess
Abstract
Background: Although most breast abscesses can be treated with the current first-line treatment of antibiotics by needle aspiration, the therapeutic duration is lengthy and recurrences often occur. Therefore, we aimed to investigate the clinical efficacy of the Mammotome biopsy system (Johnson & Johnson Corp., New Brunswick, NJ) in a cohort of patients with breast abscesses.
Methods: Forty lactating and 30 nonlactating breast abscess patients with unfavorable outcomes with antibiotic treatment and/or needle aspiration failure were recruited and treated with the Mammotome biopsy system.
Results: Skin inflammation of all patients disappeared within 6 days with no recurrence. The clinical outcomes in patients with an abscess size ≤ 3.5 cm was significantly better than those with an abscess size >3.5 cm (P = .025).
Conclusions: The Mammotome biopsy system, an effective treatment strategy that is minimally invasive and less damaging, in combination with appropriate antibiotic therapy can be used safely as the first-line approach to breast abscess management.
Copyright © 2013 Elsevier Inc. All rights reserved.