Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2012 Dec 24:414:273-80.
doi: 10.1016/j.cca.2012.09.026. Epub 2012 Oct 2.

LC-MS/MS analysis of plasma lyso-Gb3 in Fabry disease

Affiliations

LC-MS/MS analysis of plasma lyso-Gb3 in Fabry disease

Michel Boutin et al. Clin Chim Acta. .

Abstract

Background: Fabry disease is a complex, multisystemic and clinically heterogeneous disease, with elevated excretion of globotriaosylceramide (Gb(3)) and globotriaosylsphingosine (lyso-Gb(3)) accumulating in biological fluids caused by deficiency of the enzyme, lysosomal α-galactosidase A. Our aims were to propose a tandem mass spectrometry fragmentation mechanism for lyso-Gb(3), to develop and validate a simple, and robust methodology for the measurement of plasma lyso-Gb(3) using LC-MS/MS in large Fabry cohorts and in controls. Response to treatment was also evaluated.

Method: A solid-phase extraction procedure was used to process plasma samples. The 1-β-D-glucosylsphingosine (GSG) internal standard was chosen for its commercial availability. A liquid chromatography method was devised to allow the co-elution of the GSG internal standard with lyso-Gb(3), thus compensating for system variability and reducing the matrix effect. A multiple reaction monitoring method was developed, working in positive electrospray ionization.

Results: The validation of the method provided good accuracy and precision: intraday and interday biases of less than 8% and 5%, respectively, and intraday and interday CVs of <12% and 7%, respectively. Limit of detection was 0.7 nmol/l and limit of quantification was 2.5 nmol/l. Plasma samples were stable for up to 6h at room temperature, 48 h at 4 °C, and 20 weeks at -20 °C. Regarding untreated Fabry patients, the mean lyso-Gb(3) concentrations were 170 nmol/l for males and 9.7 nmol/l for females, and for treated patients, 40.2 nmol/l for males and 7.5 nmol/l for females.

Conclusion: A robust LC-MS/MS methodology is presented for plasma lyso-Gb(3) quantification.

PubMed Disclaimer

Publication types

LinkOut - more resources