Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2013 Apr;251(4):1103-7.
doi: 10.1007/s00417-012-2167-5. Epub 2012 Oct 11.

Pain score of patients undergoing single spot, short pulse laser versus conventional laser for diabetic retinopathy

Affiliations
Randomized Controlled Trial

Pain score of patients undergoing single spot, short pulse laser versus conventional laser for diabetic retinopathy

Ahmad Mirshahi et al. Graefes Arch Clin Exp Ophthalmol. 2013 Apr.

Abstract

Background: To compare pain score of single spot short duration time (20 milliseconds) panretinal photocoagulation (PRP) with conventional (100 milliseconds) PRP in diabetic retinopathy.

Methods: Sixty-six eyes from 33 patients with symmetrical severe non-proliferative diabetic retinopathy (non-PDR) or proliferative diabetic retinopathy (PDR) were enrolled in this prospective randomized controlled trial. One eye of each patient was randomized to undergo conventional and the other eye to undergo short time PRP. Spot size of 200 μm was used in both laser types, and energy was adjusted to achieve moderate burn on the retina. Patients were asked to mark the level of pain felt during the PRP session for each eye on the visual analog scale (VAS) and were examined at 1 week, and at 1, 2, 4 and 6 months.

Results: Sixteen women and 17 men with mean age 58.9 ± 7.8 years were evaluated. The conventional method required a mean power of 273 ± 107 mW, whereas the short duration method needed 721 ± 406 mW (P = 0.001). An average of 1,218 ± 441 spots were delivered with the conventional method and an average of 2,125 ± 503 spots were required with the short duration method (P = 0.001). Average pain score was 7.5 ± 1.14 in conventional group and 1.75 ± 0.87 in the short duration group (P = 0.001). At 1 week, 1 month, and 4 months following PRP, the mean changes of central macular thickness (CMT) from baseline in the conventional group remained 29.2 μm (P = 0.008), 40.0 μm (P = 0.001), and 40.2 μm (P = 0.007) greater than the changes in CMT for short time group.

Conclusion: Patient acceptance of short time single spot PRP was high, and well-tolerated in a single session by all patients. Moreover, this method is significantly less painful than but just as effective as conventional laser during 6 months of follow-up. The CMT change was more following conventional laser than short time laser.

PubMed Disclaimer

References

    1. Proc Natl Acad Sci U S A. 1993 Sep 15;90(18):8643-7 - PubMed
    1. Ophthalmology. 2009 Jun;116(6):1168-74 - PubMed
    1. Arch Ophthalmol. 1986 Jul;104(7):997-1003 - PubMed
    1. Eye (Lond). 2008 Jan;22(1):96-9 - PubMed
    1. Br J Ophthalmol. 2010 Nov;94(11):1493-8 - PubMed

Publication types

Substances