A new radioimmunoassay for the detection of small amounts of white cells and platelets in red cell concentrates: implications for blood transfusion
- PMID: 2305440
- DOI: 10.1046/j.1537-2995.1990.30290162896.x
A new radioimmunoassay for the detection of small amounts of white cells and platelets in red cell concentrates: implications for blood transfusion
Abstract
In the procedure for quality control of red cell concentrates, made white cell (WBC)-poor by filtration, the particle-counting technique was found to be insufficiently sensitive in detecting the remaining WBCs and platelets. Therefore, direct radioimmunoassays were developed using murine monoclonal antibodies specific for platelets, granulocytes, and T lymphocytes. The sensitivity for platelets was 40 x 10(3) per mL, that for granulocytes was 10 x 10(3) per mL (starting from 0.2 mL of red cell filtrate), and that for T lymphocytes was 0.006 x 10(6) per mL (starting from 5 mL) and 0.0015 x 10(6) per mL (starting from 50 mL). These direct assays were used in experiments on filtration with three types of filters: the Cellselect B-1005, B-1014 and the B-1013 (bedside filter). After filtration of 1 unit of blood cell suspension through the B-1005, the number of remaining platelets was found to vary between less than or equal to 0.04 x 10(6) and greater than 15 x 10(6) per mL (n = 16); after filtration through the B-1013 filter, the remaining platelets were greater than 0.04 x 10(6) per mL. Upon filtration of a second unit of blood cell suspension through the B-1013 filter, the number of remaining platelets varied between less than or equal to 0.04 x 10(6) and 5 x 10(6). In both filter types, the number of remaining granulocytes was always less than 0.01 x 10(6) per mL. A study of T-lymphocyte contamination revealed that, upon filtration of 1 unit of blood through the B-1005, T-lymphocyte numbers were less than or equal to 0.0015 x 10(6) to 0.15 x 10(6) per mL (starting from 5 and 50 mL); upon filtration through the B-1013 filter, the number of remaining T lymphocytes varied between less than or equal to 0.006 x 10(6) and 0.2 x 10(6) per mL (starting from 5 mL). After filtration of a second unit of blood cell suspension through the B-1013 filter, the number of remaining T lymphocytes ranged from less than or equal to 0.006 x 10(6) to 0.1 to 0.5 x 10(6) per mL (starting from 5 mL). The direct radioimmunoassay is an improvement over the present electronic particle-counting techniques with regard to both sensitivity and specificity and may therefore be useful in quality control procedures in blood transfusion as well as in the development of new filters.
Similar articles
-
Histologic and immunohistochemical studies on the preparation of white cell-poor red cell concentrates: the filtration process using three different polyester filters.Transfusion. 1991 Jan;31(1):40-6. doi: 10.1046/j.1537-2995.1991.31191096184.x. Transfusion. 1991. PMID: 1986463
-
Amount and type of leukocytes in 'leukocyte-free' red cell and platelet concentrates.Vox Sang. 1987;53(2):76-82. doi: 10.1111/j.1423-0410.1987.tb04922.x. Vox Sang. 1987. PMID: 3686937
-
Mechanisms of white cell reduction in red cell concentrates by filtration: the effect of the cellular composition of the red cell concentrates.Transfusion. 1993 Jan;33(1):42-50. doi: 10.1046/j.1537-2995.1993.33193142309.x. Transfusion. 1993. PMID: 8424266
-
Leukocyte depletion for safe blood transfusion.Biotechnol J. 2009 Aug;4(8):1140-51. doi: 10.1002/biot.200800182. Biotechnol J. 2009. PMID: 19418471 Review.
-
Platelet storage lesion: an update on the impact of various leukoreduction processes on the biological response modifiers.Transfus Apher Sci. 2006 Feb;34(1):125-30. doi: 10.1016/j.transci.2005.09.002. Epub 2005 Dec 20. Transfus Apher Sci. 2006. PMID: 16376152 Review.
Cited by
-
Reduction of HTLV-I-infected cells in blood by leukocyte filtration.Ann Hematol. 1993 Dec;67(6):295-300. doi: 10.1007/BF01696350. Ann Hematol. 1993. PMID: 8280813
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical