. 2013 Feb;471(2):621-7.
doi: 10.1007/s11999-012-2609-8. Epub 2012 Oct 2.

Limb Lengthening and Reconstruction Society AIM index reliably assesses lower limb deformity

Affiliations

Limb Lengthening and Reconstruction Society AIM index reliably assesses lower limb deformity

James J McCarthy et al. Clin Orthop Relat Res. 2013 Feb.

Abstract

Background: Although several systems exist for classifying specific limb deformities, there currently are no validated rating scales for evaluating the complexity of general lower limb deformities. Accurate assessment of the complexity of a limb deformity is essential for successful treatment. A committee of the Limb Lengthening and Reconstruction Society (LLRS) therefore developed the LLRS AIM Index to quantify the severity of a broad range of lower extremity deformities in seven domains.

Questions/purposes: We addressed two questions: (1) Does the LLRS AIM Index show construct validity by correlating with rankings of case complexity? (2) Does the LLRS AIM Index show sufficient interrater and intrarater reliabilities?

Methods: We had eight surgeons evaluate 10 fictionalized patients with various lower limb deformities. First, they ranked the cases from simplest to most complex, and then they rated the cases using the LLRS AIM Index. Two or more weeks later, they rated the cases again. We assessed reliability using the Kendall's W test.

Results: Raters were consistent in their rankings of case complexity (W = 0.33). Patient rankings also correlated with both sets of LLRS AIM ratings (r(2) = 0.25; r(2) = 0.23). The LLRS AIM Index showed interrater reliability with an intraclass correlation (ICC) of 0.97 for Trial 1 and 0.98 for Trial 2 and intrarater reliability with an ICC of 0.94. The LLRS AIM Index ratings also were highly consistent between the attending surgeons and surgeons-in-training (ICC = 0.91).

Conclusions: Our preliminarily observations suggest that the LLRS AIM Index reliably classifies the complexity of lower limb deformities in and between observers.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Achterman C, Kalamchi A. Congenital deficiency of the fibula. J Bone Joint Surg Br. 1979;61:133–137. - PubMed
    1. Aitken GT. Proximal femoral focal deficiency: definition, classification, and management. In: Aitken GT, editor. Proximal Femoral Focal Deficiency: A Congenital Anomaly. Washington, DC: National Academy of Sciences; 1969. pp. 1–22.
    1. Andersen KS. Radiological classification of congenital pseudarthrosis of the tibia. Acta Orthop Scand. 1973;44:719–727. doi: 10.3109/17453677308989112. - DOI - PubMed
    1. Bhave A, Paley D, Herzenberg JE. Improvement in gait parameters after lengthening for the treatment of limb-length discrepancy. J Bone Joint Surg Am. 1999;81:529–534. - PubMed
    1. Birch JG, Lincoln TL, Mack PW, Birch CM. Congenital fibular deficiency: a review of thirty years’ experience at one institution and a proposed classification system based on clinical deformity. J Bone Joint Surg Am. 2011;93:1144–1151. doi: 10.2106/JBJS.J.00683. - DOI - PubMed

MeSH terms