. 2013 May;471(5):1498-503.
doi: 10.1007/s11999-012-2629-4.

No better flexion or function of high-flexion designs in Asian patients with TKA

Affiliations

No better flexion or function of high-flexion designs in Asian patients with TKA

Jong-Keun Seon et al. Clin Orthop Relat Res. 2013 May.

Abstract

Background: Recently, high-flexion PCL-retaining (CR) and -substituting (PS) knee prostheses were designed to allow greater and safer flexion after TKA. However, the advantages of high-flexion TKA over standard design have been debated in terms of early maximal flexion. A recent study reported a high incidence of early loosening of the femoral component related to the deep flexion provided by high-flexion PS TKA.

Questions/purposes: We determined whether high-flexion fixed bearing CR and PS prostheses would provide (1) a better flexion, (2) a better function, and (3) a higher incidence of radiographic loosening than TKA performed using standard fixed bearing CR prostheses in Asian patients.

Methods: From a total of 182 patients with primary unilateral TKA, we retrospectively reviewed 137 TKAs: 47 with high-flexion CR, 42 with high-flexion PS, and 48 with standard CR designs. ROM, Knee Society scores, and WOMAC scores were evaluated and compared among the three groups. Radiographically, we assessed radiolucent zones and component loosening. Minimum followup was 5 years (mean, 6.2 years; range, 5-8 years).

Results: We found no differences among the three groups in mean maximal flexion (high-flexion CR: 135°; high-flexion PS: 134°; standard CR: 136°), Knee Society scores, and WOMAC scores at last followup. Also, there were no differences among the three groups in terms of radiolucent lines around the prosthesis. No patient in any group had loosening of the femoral component.

Conclusions: The high-flexion CR or PS design had no advantages over the standard CR design with respect to ROM, clinical scores, and radiolucent lines around the femoral or tibial component after 5 years' followup.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Aglietti P, Buzzi R, De Felice R, Giron F. The Insall-Burstein total knee replacement in osteoarthritis: a 10-year minimum follow-up. J Arthroplasty. 1999;14:560–565. doi: 10.1016/S0883-5403(99)90077-3. - DOI - PubMed
    1. Anouchi YS, McShane M, Kelly F, Jr, Elting J, Stiehl J. Range of motion in total knee replacement. Clin Orthop Relat Res. 1996;331:87–92. doi: 10.1097/00003086-199610000-00012. - DOI - PubMed
    1. Banks S, Bellemans J, Nozaki H, Whiteside LA, Harman M, Hodge WA. Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties. Clin Orthop Relat Res. 2003;410:131–138. doi: 10.1097/01.blo.0000063121.39522.19. - DOI - PubMed
    1. Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840. - PubMed
    1. Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007;15:350–355. doi: 10.1007/s00167-006-0202-y. - DOI - PubMed