Meta-Analysis
. 2013 Apr;58(4):1026-34.
doi: 10.1007/s10620-012-2439-2. Epub 2012 Oct 21.

Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis

Kajsa E Affolter et al. Dig Dis Sci. 2013 Apr.

Abstract

Background: Several recent studies have investigated the utility of 19-, 22-, and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of pancreatic and peri-pancreatic tumors.

Aim: The objective of this study was to summarize data from these studies and estimate the effect of needle size on reported outcomes such as accuracy, adequacy, and complications.

Methods: Systematic review and meta-analysis comparing the effect of needle size (19, 22, and 25G) on diagnostic accuracy, adequacy, number of needle passes, and complications.

Results: 25G appear to confer an advantage in adequacy rates relative to 22G needles (risk difference = 0.12 %, 95 % CI 0.01, 0.25). There was no significant difference in accuracy with an overall sensitivity and specificity for 22G being 0.78 (95 % CI 0.74-0.81) and 1.00 (95 % CI 0.98-1.00) and an overall sensitivity and specificity for 25G being 0.91 (95 % CI 0.87-0.94) and 1.00 (95 % CI 0.97-1.00). There was no difference in number of passes or complications between 25 and 22G. The limited data available regarding 19G needles do not show evidence of improved outcomes with these devices.

Conclusions: In the evaluation of pancreatic and peri-pancreatic lesions by EUS-FNA, 25G needles may confer an advantage in adequacy relative to 22G needles but confer no advantages with respect to accuracy, number of passes, or complications.

PubMed Disclaimer

References

    1. Stat Med. 2002 Jun 15;21(11):1539-58 - PubMed
    1. Ann Intern Med. 2008 Dec 16;149(12):889-97 - PubMed
    1. Gastrointest Endosc. 2009 Dec;70(6):1098-100 - PubMed
    1. Endoscopy. 2009 May;41(5):445-8 - PubMed
    1. Am J Gastroenterol. 2010 Aug;105(8):1739-45 - PubMed