On-line blood viscosity monitoring in vivo with a central venous catheter, using electrical impedance technique
- PMID: 23089327
- DOI: 10.1016/j.bios.2012.09.033
On-line blood viscosity monitoring in vivo with a central venous catheter, using electrical impedance technique
Abstract
Blood viscosity is an important determinant of microvascular hemodynamics and also reflects systemic inflammation. Viscosity of blood strongly depends on the shear rate and can be characterized by a two parameter power-law model. Other major determinants of blood viscosity are hematocrit, level of inflammatory proteins and temperature. In-vitro studies have shown that these major parameters are related to the electrical impedance of blood. A special central venous catheter was developed to measure electrical impedance of blood in-vivo in the right atrium. Considering that blood viscosity plays an important role in cerebral blood flow, we investigated the feasibility to monitor blood viscosity by electrical bioimpedance in 10 patients during the first 3 days after successful resuscitation from a cardiac arrest. The blood viscosity-shear rate relationship was obtained from arterial blood samples analyzed using a standard viscosity meter. Non-linear regression analysis resulted in the following equation to estimate in-vivo blood viscosity (Viscosity(imp)) from plasma resistance (R(p)), intracellular resistance (R(i)) and blood temperature (T) as obtained from right atrium impedance measurements: Viscosity(imp)=(-15.574+15.576R(p)T)SR ((-.138RpT-.290Ri)). This model explains 89.2% (R(2)=.892) of the blood viscosity-shear rate relationship. The explained variance was similar for the non-linear regression model estimating blood viscosity from its major determinants hematocrit and the level of fibrinogen and C-reactive protein (R(2)=.884). Bland-Altman analysis showed a bias between the in-vitro viscosity measurement and the in-vivo impedance model of .04 mPa s at a shear rate of 5.5s(-1) with limits of agreement between -1.69 mPa s and 1.78 mPa s. In conclusion, this study demonstrates the proof of principle to monitor blood viscosity continuously in the human right atrium by a dedicated central venous catheter equipped with an impedance measuring device. No safety problems occurred and there was good agreement with in-vitro measurements of blood viscosity.
Copyright © 2012 Elsevier B.V. All rights reserved.
Similar articles
-
Catheter-based impedance measurements in the right atrium for continuously monitoring hematocrit and estimating blood viscosity changes; an in vivo feasibility study in swine.Biosens Bioelectron. 2004 Jul 15;19(12):1685-93. doi: 10.1016/j.bios.2004.01.002. Biosens Bioelectron. 2004. PMID: 15142603
-
On-line electrical impedance measurement for monitoring blood viscosity during on-pump heart surgery.Eur Surg Res. 2004 Sep-Oct;36(5):259-65. doi: 10.1159/000079910. Eur Surg Res. 2004. PMID: 15359088
-
Leg electrical resistance predicts venous blood viscosity and hematocrit.Clin Hemorheol Microcirc. 2019;71(4):397-402. doi: 10.3233/CH-199003. Clin Hemorheol Microcirc. 2019. PMID: 31006677
-
Plasma viscosity: a forgotten variable.Clin Hemorheol Microcirc. 2008;39(1-4):243-6. Clin Hemorheol Microcirc. 2008. PMID: 18503132 Review.
-
New trends in clinical hemorheology: an introduction to the concept of the hemorheological profile.Schweiz Med Wochenschr Suppl. 1991;43:41-9. Schweiz Med Wochenschr Suppl. 1991. PMID: 1843037 Review.
Cited by
-
A portable rotating disc as blood rheometer.Biomicrofluidics. 2019 Dec 2;13(6):064120. doi: 10.1063/1.5128937. eCollection 2019 Nov. Biomicrofluidics. 2019. PMID: 31803338 Free PMC article.
-
Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel.Biomicrofluidics. 2013 Jul 26;7(4):44106. doi: 10.1063/1.4816713. eCollection 2013. Biomicrofluidics. 2013. PMID: 24404040 Free PMC article.
-
Standardized viscosity as a source of error in computational fluid dynamic simulations of cerebral aneurysms.Med Phys. 2024 Feb;51(2):1499-1508. doi: 10.1002/mp.16926. Epub 2023 Dec 27. Med Phys. 2024. PMID: 38150511 Free PMC article.
-
Microfluidic-Based Biosensor for Blood Viscosity and Erythrocyte Sedimentation Rate Using Disposable Fluid Delivery System.Micromachines (Basel). 2020 Feb 20;11(2):215. doi: 10.3390/mi11020215. Micromachines (Basel). 2020. PMID: 32093288 Free PMC article.
-
Microfluidic-Based Biosensor for Sequential Measurement of Blood Pressure and RBC Aggregation Over Continuously Varying Blood Flows.Micromachines (Basel). 2019 Aug 30;10(9):577. doi: 10.3390/mi10090577. Micromachines (Basel). 2019. PMID: 31480325 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials