Centering Ability and Influence of Experience When Using WaveOne Single-File Technique in Simulated Canals
- PMID: 23118749
- PMCID: PMC3479955
- DOI: 10.1155/2012/206321
Centering Ability and Influence of Experience When Using WaveOne Single-File Technique in Simulated Canals
Abstract
Introduction. WaveOne is a single endodontic instrument that reciprocates with a dedicated motor to shape root canal systems. The present study assessed the centering ability of this simplified protocol along with the effect of experience in simulated plastic canals. Methods. One experienced operator shaped two groups of simulated canals. Groups 1 and 3 each comprised 30 blinded L-shaped canals or S-shaped canals, respectively. Photographs were taken before and after shaping and digitally assessed centering after superimposition of the pictures. Time of shaping, number of passes, canal aberrations, and instrument degradation were recorded. In group 2 shaping was done on 30 blinded L-shaped canals by 30 different students with no prior experience with WaveOne. Results. All three groups yielded satisfactory, reproducible shaping. Centering ratios were low and homogeneous in all groups, with no significant differences between the experienced operator and the students. Apical transportation values were very low (≤0.138 mm) with no instances of blockage or separation. The average shaping time was short (43 to 101,6 sec). Conclusions. Within the limits of the study, the WaveOne instrument had excellent centering ability with a low risk of fracture or blockage and a short shaping time, regardless of the operator's level of experience.
Figures





References
-
- Schilder H. Cleaning and shaping the root canal. Dental Clinics of North America. 1974;18(2):269–296. - PubMed
-
- Schäfer E. Shaping ability of Hero 642 rotary nickel-titanium instruments and stainless steel hand K-Flexofiles in simulated curved root canals. Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontics. 2001;92(2):215–220. - PubMed
-
- Bergmans L, Van Cleynenbreugel J, Wevers M, Lambrechts P. Mechanical root canal preparation with NiTi rotary instruments: rationale, performance and safety. Status Report for the American Journal of Dentistry. American Journal of Dentistry. 2001;14(5):324–333. - PubMed
-
- Guelzow A, Stamm O, Martus P, Kielbassa AM. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation. International Endodontic Journal. 2005;38(10):743–752. - PubMed
-
- Tzanetakis GN, Kontakiotis EG, Maurikou DV, Marzelou MP. Prevalence and management of instrument fracture in the postgraduate endodontic program at the dental school of athens: a five-year retrospective clinical study. Journal of Endodontics. 2008;34(6):675–678. - PubMed
LinkOut - more resources
Full Text Sources