Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 1990 Feb;28(2):207-10.
doi: 10.1128/jcm.28.2.207-210.1990.

Comparison of the staphylocoagulase activities of Staphylococcus aureus and Staphylococcus intermedius on Chromozym-TH

Affiliations
Comparative Study

Comparison of the staphylocoagulase activities of Staphylococcus aureus and Staphylococcus intermedius on Chromozym-TH

J Raus et al. J Clin Microbiol. 1990 Feb.

Abstract

The staphylocoagulases of Staphylococcus intermedius (39 strains from clinical samples from dogs and 1 strain from a pigeon) and Staphylococcus aureus (40 strains from nine different animal species) were compared by using the chromogenic methods of Engels et al. (W. Engels, M. Kemps, and C. P. A. van Boven, J. Clin. Microbiol. 14:496-500, 1981). S. intermedius produced staphylocoagulase which resembled that of S. aureus in its rate and method of action on prothrombin, but S. intermedius produced it in lesser amounts. Therefore, chromogenic substrate tests such as Chromozym-TH (Boehringer GmbH, Mannheim, Federal Republic of Germany) (as described by Engels et al.) can be used for the detection of staphylocoagulase in both of these species. However, to detect accurately the presence of S. intermedius staphylocoagulase by this method, preconcentration of the extracellular proteins or an extension of the reaction time of the test would be required. The method described by Engels et al. was designed specifically for clinical laboratories that handle human samples. Under those circumstances the method could be regarded as specific, enabling an identification of S. aureus only. However, as both S. aureus and S. intermedius give positive results in this test, in veterinary diagnostic laboratories, heavy reliance must not be placed on this test for determination of organisms to the species level.

PubMed Disclaimer

References

    1. Rev Fr Etud Clin Biol. 1967 Jun-Jul;12(6):544-58 - PubMed
    1. Biochim Biophys Acta. 1975 Jan 30;379(1):180-8 - PubMed
    1. J Clin Microbiol. 1979 Jan;9(1):15-9 - PubMed
    1. J Biol Chem. 1951 Nov;193(1):265-75 - PubMed
    1. J Clin Microbiol. 1981 Nov;14(5):496-500 - PubMed

Publication types

MeSH terms

LinkOut - more resources