Influence of orifice geometry and flow rate on effective valve area: an in vitro study
Abstract
Fluid dynamics suggests that orifice geometry is a determinant of discharge properties and, therefore, should influence empiric constants in formulas (such as the Gorlin formula) to calculate stenotic valve area. An in vitro study utilizing a model of transmitral flow was conducted to investigate how the discharge coefficient changes with 1) orifice eccentricity (ratio of long to short diameter), 2) absolute area, 3) the presence of a nozzle-like inlet, and 4) varying flow. Twenty-three orifices with areas varying between 0.3 and 2.5 cm2 and eccentricities from 1:1, or circular, to 5:1, or elliptic, were tested. The calculated discharge coefficients ranged between 0.675 and 0.93. For a given area, the discharge coefficient decreased by a mean value (+/- SD) of 5.5 +/- 1.3% between circular orifices and 5:1 ellipses. Discharge coefficients increased by a mean of 8.9 +/- 3.5% from 0.3 to 2.5 cm2 area within each eccentricity class. A gradually tapering inlet (nozzle) raised the discharge coefficient by 8.8 +/- 3.9%, leading to a discharge coefficient between 0.81 and 0.93 for round orifices. The discharge coefficient did not change appreciably with flow. The concept of the discharge coefficient and its role in assessing restrictive orifices in general by hydraulic formulas (for example, the Gorlin and pressure half-time calculations) are discussed.
Comment in
-
Further reconciliation between pathoanatomy and pathophysiology of stenotic cardiac valves.J Am Coll Cardiol. 1990 Apr;15(5):1181-2. doi: 10.1016/0735-1097(90)90261-m. J Am Coll Cardiol. 1990. PMID: 2312975 No abstract available.
Similar articles
-
When should Doppler-determined valve area be better than the Gorlin formula?: Variation in hydraulic constants in low flow states.J Am Coll Cardiol. 1987 Jun;9(6):1294-305. doi: 10.1016/s0735-1097(87)80469-2. J Am Coll Cardiol. 1987. PMID: 3294968
-
Impact of orifice geometry on the shape of jets: an in vitro Doppler color flow study.J Am Coll Cardiol. 1991 Mar 15;17(4):901-8. doi: 10.1016/0735-1097(91)90872-7. J Am Coll Cardiol. 1991. PMID: 1999627
-
Doppler assessment of prosthetic valve orifice area. An in vitro study.Circulation. 1992 Jun;85(6):2275-83. doi: 10.1161/01.cir.85.6.2275. Circulation. 1992. PMID: 1591841
-
Advances in the hemodynamic assessment of stenotic cardiac valves.J Am Coll Cardiol. 1987 Oct;10(4):912-9. doi: 10.1016/s0735-1097(87)80288-7. J Am Coll Cardiol. 1987. PMID: 3309006 Review.
-
Lessons from in vitro models of small, irregular, multiple and tunnel-like stenoses relevant to clinical stenoses of valves and small vessels.J Am Coll Cardiol. 1989 Mar 1;13(3):716-22. doi: 10.1016/0735-1097(89)90616-5. J Am Coll Cardiol. 1989. PMID: 2645341 Review.
Cited by
-
An Introductory Overview of Image-Based Computational Modeling in Personalized Cardiovascular Medicine.Front Bioeng Biotechnol. 2020 Sep 25;8:529365. doi: 10.3389/fbioe.2020.529365. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 33102452 Free PMC article. Review.
-
Bicuspid aortic valve morphology and hemodynamics by same-day echocardiography and cardiac MRI.Int J Cardiovasc Imaging. 2022 Sep;38(9):2047-2056. doi: 10.1007/s10554-022-02593-0. Epub 2022 Mar 16. Int J Cardiovasc Imaging. 2022. PMID: 35294708
-
Fluid Structure Interaction on Paravalvular Leakage of Transcatheter Aortic Valve Implantation Related to Aortic Stenosis: A Patient-Specific Case.Comput Math Methods Med. 2020 May 4;2020:9163085. doi: 10.1155/2020/9163085. eCollection 2020. Comput Math Methods Med. 2020. PMID: 32454886 Free PMC article.
-
Assessing mitral valve area and orifice geometry in calcific mitral stenosis: a new solution by real-time three-dimensional echocardiography.J Am Soc Echocardiogr. 2008 Sep;21(9):1006-9. doi: 10.1016/j.echo.2008.05.010. Epub 2008 Jul 14. J Am Soc Echocardiogr. 2008. PMID: 18620839 Free PMC article.
-
In vivo fluid dynamics of the Ventura interatrial shunt device in patients with heart failure.ESC Heart Fail. 2024 Oct;11(5):2499-2509. doi: 10.1002/ehf2.14859. Epub 2024 May 22. ESC Heart Fail. 2024. PMID: 38773938 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources