This prospective study was designed to evaluate 196 Anatomique Benoist Giraud (ABG II) total hip arthroplasties which were implanted between September 1999 and December 2000. A minimum 11 years follow up was completed in 183 cases. The bearing surfaces were polyethylene-zirconia in 84 cases, polyethylene-metal in 42 and ceramic-ceramic in 57. Changes in the femoral stem design, in relation to the previous ABG I model, have led to a significant improvement in stress-shielding. Polyethylene wear rate was lower by more than 50% compared with non-crosslinked polyethylene. Excellent and good results were obtained in 90.32% of cases, and implant survival was 98.39% at the end of follow-up.
Keywords: anatomical-THA; femur remodeling; hydroxyapatite coating; long term outcomes; polyethylene wear.
Copyright © 2013 Elsevier Inc. All rights reserved.
Similar articles
-
Ten-year survivorship of the Anatomique Benoist Girard I total hip arthroplasty.J Arthroplasty. 2007 Apr;22(3):363-8. doi: 10.1016/j.arth.2006.05.022. J Arthroplasty. 2007. PMID: 17400092
-
Comparison of Hydroxyapatite-coated stems in total hip arthroplasty after a minimum 10-years follow-up.Acta Chir Orthop Traumatol Cech. 2008 Oct;75(5):339-46. Acta Chir Orthop Traumatol Cech. 2008. PMID: 19026187
-
Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register.Acta Orthop. 2006 Feb;77(1):57-70. doi: 10.1080/17453670610045704. Acta Orthop. 2006. PMID: 16534703
-
[Tribology in hip arthroplasty : Benefits of different materials].Orthopade. 2021 Apr;50(4):259-269. doi: 10.1007/s00132-021-04077-w. Epub 2021 Feb 25. Orthopade. 2021. PMID: 33630110 Review. German.
-
Basic principles and uniform terminology for the head-neck junction in hip replacement.Hip Int. 2015 Mar-Apr;25(2):115-9. doi: 10.5301/hipint.5000204. Epub 2014 Nov 1. Hip Int. 2015. PMID: 25362881 Review.
Cited by
-
Cementless hydroxyapatite coated hip prostheses.Biomed Res Int. 2015;2015:386461. doi: 10.1155/2015/386461. Epub 2015 Feb 23. Biomed Res Int. 2015. PMID: 25802848 Free PMC article.
-
[Comparison of filling ratio, alignment, and stability between ABG Ⅱ short-stem and Corail long-stem in total hip arthroplasty for Dorr type C femur].Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2023 Jun 15;37(6):641-646. doi: 10.7507/1002-1892.202303123. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2023. PMID: 37331936 Free PMC article. Chinese.
-
Surgeon-Stratified Periprosthetic Fracture Risk in a Single-Hospital Cohort of 1531 Uncemented ABG-II Femoral Stems at Primary Total Hip Arthroplasty.Indian J Orthop. 2023 Sep 19;57(11):1850-1857. doi: 10.1007/s43465-023-00996-2. eCollection 2023 Nov. Indian J Orthop. 2023. PMID: 37881273 Free PMC article.
-
Clinical results at 10 years of minimum follow-up with the ABG 2 hip arthroplasty, matched with ceramic-on-ceramic bearings.SICOT J. 2022;8:32. doi: 10.1051/sicotj/2022032. Epub 2022 Aug 15. SICOT J. 2022. PMID: 35969123 Free PMC article.
-
Bioactive Glass and Silicate-Based Ceramic Coatings on Metallic Implants: Open Challenge or Outdated Topic?Materials (Basel). 2019 Sep 10;12(18):2929. doi: 10.3390/ma12182929. Materials (Basel). 2019. PMID: 31510062 Free PMC article. Review.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical