320-detector row CT angiography for detection and evaluation of intracranial aneurysms: comparison with conventional digital subtraction angiography
- PMID: 23142024
- DOI: 10.1016/j.crad.2012.09.001
320-detector row CT angiography for detection and evaluation of intracranial aneurysms: comparison with conventional digital subtraction angiography
Abstract
Aim: To compare the diagnostic performance of 320-detector row computed tomographic angiography (CTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms.
Materials and methods: Fifty-two consecutive patients with non-traumatic subarachnoid haemorrhage (SAH) and suspected intracranial aneurysms were evaluated from January 2009 to October 2011. All underwent both 320-detector row volume CTA examination and DSA. CTA volume data were transmitted to a VITREA workstation and two physicians with experience in diagnostic imaging of the nervous system independently carried out image post-processing and assessed the results. The three-dimensional (3D) CTA and DSA images were assessed using intraoperative findings as the reference standard.
Results: In 52 patients, 54 aneurysms were detected; 48 patients underwent surgery for 50 aneurysms. The overall sensitivity, specificity, and accuracy of 3D CTA were 96.3, 100, and 94.6%, respectively. Meanwhile, the overall sensitivity, specificity, and accuracy of DSA were 98.1, 98.1, and 95.1%, respectively. For aneurysms less than 3 mm, the sensitivity, specificity, and accuracy of 3D CTA were 81.8, 100, and 93.3%, respectively. The sensitivity, specificity, and accuracy of DSA for small aneurysms were 90.9, 100, and 96.2%, respectively. 3D CTA was superior to DSA in demonstrating aneurysmal calcification, parent artery, and surrounding vascular anatomy.
Conclusions: 3D CTA is a highly sensitive, specific, and non-invasive imaging method for diagnosis and evaluation of intracranial aneurysms. It also allows for precise depiction of aneurysm morphology. Therefore, 320-detector row CTA may be used as an alternative to DSA as a first-line imaging technique in patients with SAH.
Copyright © 2012 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Comparison of the accuracy of subtraction CT angiography performed on 320-detector row volume CT with conventional CT angiography for diagnosis of intracranial aneurysms.Eur J Radiol. 2012 Jan;81(1):118-22. doi: 10.1016/j.ejrad.2011.05.003. Epub 2011 May 31. Eur J Radiol. 2012. PMID: 21632193
-
Dual-energy CT angiography in the evaluation of intracranial aneurysms: image quality, radiation dose, and comparison with 3D rotational digital subtraction angiography.AJR Am J Roentgenol. 2010 Jan;194(1):23-30. doi: 10.2214/AJR.08.2290. AJR Am J Roentgenol. 2010. PMID: 20028901
-
Detection of intracranial aneurysms using three-dimensional multidetector-row CT angiography: is bone subtraction necessary?Eur J Radiol. 2011 Aug;79(2):e18-23. doi: 10.1016/j.ejrad.2010.01.004. Epub 2010 Feb 9. Eur J Radiol. 2011. PMID: 20144517
-
Can computed tomography angiography of the brain replace lumbar puncture in the evaluation of acute-onset headache after a negative noncontrast cranial computed tomography scan?Acad Emerg Med. 2010 Apr;17(4):444-51. doi: 10.1111/j.1553-2712.2010.00694.x. Acad Emerg Med. 2010. PMID: 20370785 Review.
-
Comprehensive review of imaging of intracranial aneurysms and angiographically negative subarachnoid hemorrhage.Neurosurg Focus. 2019 Dec 1;47(6):E20. doi: 10.3171/2019.9.FOCUS19653. Neurosurg Focus. 2019. PMID: 31786554 Review.
Cited by
-
Spontaneous Coronary Artery Dissection: Current State of the Science: A Scientific Statement From the American Heart Association.Circulation. 2018 May 8;137(19):e523-e557. doi: 10.1161/CIR.0000000000000564. Epub 2018 Feb 22. Circulation. 2018. PMID: 29472380 Free PMC article. Review.
-
Detection of remnants in clipped unruptured intracranial aneurysms by intraoperative CT-angiography and postoperative DSA: clinical relevance and follow-up.Acta Neurochir (Wien). 2025 Apr 17;167(1):109. doi: 10.1007/s00701-025-06518-3. Acta Neurochir (Wien). 2025. PMID: 40240681 Free PMC article.
-
Is four-dimensional CT angiography as effective as digital subtraction angiography in the detection of the underlying causes of intracerebral haemorrhage: a systematic review.Neuroradiology. 2020 Mar;62(3):273-281. doi: 10.1007/s00234-019-02349-z. Epub 2020 Jan 4. Neuroradiology. 2020. PMID: 31901972 Free PMC article.
-
Intra- and inter-observer variability in intracranial aneurysm segmentation: comparison between CT angiography (semi-automated segmentation software stroke VCAR) and digital subtraction angiography (3D rotational angiography).Radiol Med. 2021 Mar;126(3):484-493. doi: 10.1007/s11547-020-01275-y. Epub 2020 Sep 9. Radiol Med. 2021. PMID: 32902826
-
Detection and Evaluation of Intracranial Aneurysms in the Posterior Fossa by Multidetector Computed Tomography Angiography - Comparison with Digital Subtraction Angiography.Asian J Neurosurg. 2019 Apr-Jun;14(2):491-498. doi: 10.4103/ajns.AJNS_290_18. Asian J Neurosurg. 2019. PMID: 31143268 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical