Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Jan;68(1):e15-20.
doi: 10.1016/j.crad.2012.09.001. Epub 2012 Nov 9.

320-detector row CT angiography for detection and evaluation of intracranial aneurysms: comparison with conventional digital subtraction angiography

Affiliations
Comparative Study

320-detector row CT angiography for detection and evaluation of intracranial aneurysms: comparison with conventional digital subtraction angiography

H Wang et al. Clin Radiol. 2013 Jan.

Abstract

Aim: To compare the diagnostic performance of 320-detector row computed tomographic angiography (CTA) with digital subtraction angiography (DSA) for the detection and characterization of intracranial aneurysms.

Materials and methods: Fifty-two consecutive patients with non-traumatic subarachnoid haemorrhage (SAH) and suspected intracranial aneurysms were evaluated from January 2009 to October 2011. All underwent both 320-detector row volume CTA examination and DSA. CTA volume data were transmitted to a VITREA workstation and two physicians with experience in diagnostic imaging of the nervous system independently carried out image post-processing and assessed the results. The three-dimensional (3D) CTA and DSA images were assessed using intraoperative findings as the reference standard.

Results: In 52 patients, 54 aneurysms were detected; 48 patients underwent surgery for 50 aneurysms. The overall sensitivity, specificity, and accuracy of 3D CTA were 96.3, 100, and 94.6%, respectively. Meanwhile, the overall sensitivity, specificity, and accuracy of DSA were 98.1, 98.1, and 95.1%, respectively. For aneurysms less than 3 mm, the sensitivity, specificity, and accuracy of 3D CTA were 81.8, 100, and 93.3%, respectively. The sensitivity, specificity, and accuracy of DSA for small aneurysms were 90.9, 100, and 96.2%, respectively. 3D CTA was superior to DSA in demonstrating aneurysmal calcification, parent artery, and surrounding vascular anatomy.

Conclusions: 3D CTA is a highly sensitive, specific, and non-invasive imaging method for diagnosis and evaluation of intracranial aneurysms. It also allows for precise depiction of aneurysm morphology. Therefore, 320-detector row CTA may be used as an alternative to DSA as a first-line imaging technique in patients with SAH.

PubMed Disclaimer

Similar articles

Cited by

Publication types