Abstract
Blood is a clinically-important analytical matrix that is routinely selected for disease monitoring. Having a clear understanding of the mechanisms involved in blood coagulation is a key consideration in haemostasis, with modern clinical practices requiring rapid, miniaturised and informative diagnostic platforms to reliably study changes in viscoelasticity (VE). Oscillatory transducers such as the Quartz Crystal Microbalance (QCM) have considerable potential in this area, provided that they present simple, linear rheometric readings which can be adequately analysed and interpreted. Hence, integrating QCM data obtained in the laboratory with mathematical modelling of acoustic interactions between quartz crystal surfaces and coagulating blood is an important consideration for modelling thrombus formation. Here, we provide a comprehensive overview of experimental and theoretical applications currently being employed to monitor and model the VE properties of coagulating blood when applied to a QCM resonator, with key emphasis on data modelling and interpretation.
Copyright © 2012 Elsevier Ltd. All rights reserved.
Similar articles
-
In vitro haemocompatibility evaluation of PET surfaces using the quartz crystal microbalance technique.J Biomater Sci Polym Ed. 2012;23(5):697-714. doi: 10.1163/092050611X559232. Epub 2011 Mar 4. J Biomater Sci Polym Ed. 2012. PMID: 21375809
-
Solidified liquid layer model makes quartz crystal microbalance a convenient molecular ruler.Colloids Surf B Biointerfaces. 2011 Jun 15;85(1):92-6. doi: 10.1016/j.colsurfb.2010.10.037. Epub 2010 Oct 30. Colloids Surf B Biointerfaces. 2011. PMID: 21093226
-
Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces.Biosens Bioelectron. 2005 Jul 15;21(1):79-86. doi: 10.1016/j.bios.2004.09.026. Epub 2004 Nov 11. Biosens Bioelectron. 2005. PMID: 15967354
-
A review of monolithic multichannel quartz crystal microbalance: a review.Anal Chim Acta. 2011 Feb 21;687(2):114-28. doi: 10.1016/j.aca.2010.12.022. Epub 2010 Dec 21. Anal Chim Acta. 2011. PMID: 21277413 Review.
-
Wireless-electrodeless quartz-crystal-microbalance biosensors for studying interactions among biomolecules: a review.Proc Jpn Acad Ser B Phys Biol Sci. 2013;89(9):401-17. doi: 10.2183/pjab.89.401. Proc Jpn Acad Ser B Phys Biol Sci. 2013. PMID: 24213205 Free PMC article. Review.
Cited by
-
Glyceraldehyde-derived pyridinium (GLAP) evokes oxidative stress and inflammatory and thrombogenic reactions in endothelial cells via the interaction with RAGE.Cardiovasc Diabetol. 2015 Jan 8;14:1. doi: 10.1186/s12933-014-0162-3. Cardiovasc Diabetol. 2015. PMID: 25582325 Free PMC article.
-
Shear Mode Bulk Acoustic Resonator Based on Inclined c-Axis AlN Film for Monitoring of Human Hemostatic Parameters.Micromachines (Basel). 2018 Sep 30;9(10):501. doi: 10.3390/mi9100501. Micromachines (Basel). 2018. PMID: 30424434 Free PMC article.
-
Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods.Sensors (Basel). 2016 Feb 24;16(3):282. doi: 10.3390/s16030282. Sensors (Basel). 2016. PMID: 26927107 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical