Sedation in screening colonoscopy: impact on quality indicators and complications
- PMID: 23147522
- DOI: 10.1038/ajg.2012.347
Sedation in screening colonoscopy: impact on quality indicators and complications
Abstract
Objectives: Quality indicators including cecal intubation rate (CIR) and adenoma detection rate (ADR) are established. Sex differences of quality indicators are observed, but the influence of sedation has not been investigated so far. The objective of this study is to assess the impact of sedation on quality indicators, including CIR and ADR, according to sex.
Methods: We analyzed data of 52,506 screening colonoscopies performed by 196 endoscopists between November 2007 and April 2011 according to the Austrian "quality management for colon cancer prevention" program.
Results: Sedation did not affect polyp detection rate (women P=0.7972, men P=0.3711) or ADR for both sexes (women P=0.2773, men P=0.8676). ADR was not significantly influenced by sedation (P=0.1272), but by age and sex (both P<0.0001), when the executing endoscopist was considered. Although women were more often sedated than men (90.70 vs. 81.83%; P<0.0001), CIR was slightly lower in women than in men (94.69 vs. 96.58%; P<0.0001). Sedation improved the CIR in women by 2.95% (94.96 vs. 92.01%; P<0.0001), whereas in men it was just by 1.28% (96.81 vs. 95.53%; P<0.0001). Sedated women only reached the CIR of unsedated men (94.96 vs. 95.53%; P=0.1005). Accounting for the intra-observer influence of the endoscopist, the overall CIR was influenced by the interaction of sex and age (P=0.0049), but not by sedation (P=0.1435).
Conclusions: Sedation does not increase adenoma or polyp detection, although it leads to an increase in CIR in men and women. This effect is more pronounced in women, yet CIR of men remains higher compared with women. Quality indicators are mainly influenced by the patient's age, sex, and the endoscopists' individual performance, rather than the endoscopists' subspeciality or procedural experience.
Comment in
-
Does the use of sedation, or the level of sedation, affect detection during colonoscopy?Am J Gastroenterol. 2012 Dec;107(12):1849-51. doi: 10.1038/ajg.2012.354. Am J Gastroenterol. 2012. PMID: 23211852
-
Preparation, sedation, and monitoring.Endoscopy. 2013;45(4):305-9. doi: 10.1055/s-0032-1326393. Epub 2013 Mar 26. Endoscopy. 2013. PMID: 23533077 No abstract available.
-
Response to Shaikh et al.Am J Gastroenterol. 2013 May;108(5):853-4. doi: 10.1038/ajg.2013.35. Am J Gastroenterol. 2013. PMID: 23644965 No abstract available.
-
Variable use of sedation during colonoscopy and impact on outcome.Am J Gastroenterol. 2013 May;108(5):853. doi: 10.1038/ajg.2013.33. Am J Gastroenterol. 2013. PMID: 23644966 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials
Miscellaneous