Potential column chromatography generators for ionic Ga-68. I. Inorganic substrates
- PMID: 231643
Potential column chromatography generators for ionic Ga-68. I. Inorganic substrates
Abstract
Chemical separations for Ga-68 from Ge-68 using adsorption chromatography on inorganic materials are described. The adsorbents used were TiO2, ZrO2, and SiO2. Distribution coefficients for Ge and Ga on these absorbents were determined as a function of reagent concentration and duration of equilibration. The distribution coefficient (w/w) for Ge on SiO2 reached 250 in 6 N HNO3, whereas Ga was no significantly adsorbed. Therefore, Ga-68 can be collected with a mall volume of 6 N HNO3 eluent. By contrast, large volumes of 1 N HNO3 were necessary to collect Ga-68 from ZrO2, since the KD of Ga under these circumstances was about 50. The Ga-68 eluted from TiO2 was chemically contaminated with titanates and would require additional chemical manipulation in order to make it injectable. All the adsorbents could lead to chromatographic systems that would allow acceptable chemical separations. However, the specific requirements for a radionuclide generator, usable in a hospital environment, make the SiO2-based system the most attractive.
Similar articles
-
Potential column chromatography for ionic Ga-68. II: Organic ion exchangers as chromatographic supports.J Nucl Med. 1980 Jan;21(1):81-3. J Nucl Med. 1980. PMID: 7356744
-
Quantitative online isolation of ⁶⁸Ge from ⁶⁸Ge/⁶⁸Ga generator eluates for purification and immediate quality control of breakthrough.Appl Radiat Isot. 2013 Dec;82:45-8. doi: 10.1016/j.apradiso.2013.07.020. Epub 2013 Jul 25. Appl Radiat Isot. 2013. PMID: 23948310
-
Processing of generator-produced 68Ga for medical application.J Nucl Med. 2007 Oct;48(10):1741-8. doi: 10.2967/jnumed.107.040378. Epub 2007 Sep 14. J Nucl Med. 2007. PMID: 17873136
-
Maturation of a key resource - the germanium-68/gallium-68 generator: development and new insights.Curr Radiopharm. 2012 Jul;5(3):202-11. doi: 10.2174/1874471011205030202. Curr Radiopharm. 2012. PMID: 22697481 Review.
-
(68)Ge/ (68)Ga generators: past, present, and future.Recent Results Cancer Res. 2013;194:3-16. doi: 10.1007/978-3-642-27994-2_1. Recent Results Cancer Res. 2013. PMID: 22918751 Review.
Cited by
-
Radionuclide generators: the prospect of availing PET radiotracers to meet current clinical needs and future research demands.Am J Nucl Med Mol Imaging. 2019 Feb 15;9(1):30-66. eCollection 2019. Am J Nucl Med Mol Imaging. 2019. PMID: 30911436 Free PMC article. Review.
-
A novel gallium bisaminothiolate complex as a myocardial perfusion imaging agent.Nucl Med Biol. 2008 Jan;35(1):83-90. doi: 10.1016/j.nucmedbio.2007.08.002. Epub 2007 Nov 19. Nucl Med Biol. 2008. PMID: 18158947 Free PMC article.
-
Intrinsically germanium-69-labeled iron oxide nanoparticles: synthesis and in-vivo dual-modality PET/MR imaging.Adv Mater. 2014 Aug 13;26(30):5119-23. doi: 10.1002/adma.201401372. Epub 2014 Jun 18. Adv Mater. 2014. PMID: 24944166 Free PMC article.
Publication types
MeSH terms