Clinical assessment of central venous pressure in the critically ill
- PMID: 2316561
- DOI: 10.1097/00000441-199003000-00006
Clinical assessment of central venous pressure in the critically ill
Abstract
To evaluate the accuracy of central venous pressure (CVP) assessment in critically ill patients, and measure disagreement amongst clinicians, 50 consecutive intensive care unit (ICU) patients with right internal jugular catheters were examined. CVP was measured by the indwelling catheter, and was assessed by: (1) one of three ICU staff physicians, (2) one of six medical residents, and (3) one of six medical students. There was no significant difference in CVP assessment between medical students, residents, and staff physicians. Although all clinicians tended to underestimate CVP, only the residents did so significantly (p less than 0.05). Sensitivity and specificity, and agreement and correlation between the clinicians' assessment and catheter measurements were higher when ventilated patients were excluded. All clinicians agreed more often and were better at identifying low CVP. In summary, considerable disagreement and inaccuracy exists in the clinical assessment of central venous pressure in critically ill patients.
Similar articles
-
Usefulness of the external jugular vein examination in detecting abnormal central venous pressure in critically ill patients.Arch Intern Med. 2006 Oct 23;166(19):2132-7. doi: 10.1001/archinte.166.19.2132. Arch Intern Med. 2006. PMID: 17060544 Clinical Trial.
-
Accuracy of totally implanted ports, tunnelled, single- and multiple-lumen central venous catheters for measurement of central venous pressure.Intensive Care Med. 2000 Dec;26(12):1837-42. doi: 10.1007/s001340000705. Intensive Care Med. 2000. PMID: 11271093
-
Diagnostic accuracy of a simple ultrasound measurement to estimate central venous pressure in spontaneously breathing, critically ill patients.J Hosp Med. 2009 Jul;4(6):350-5. doi: 10.1002/jhm.503. J Hosp Med. 2009. PMID: 19670356
-
Reproducibility of central venous pressures in supine and lateral positions: a pilot evaluation of the phlebostatic axis in critically ill patients.Heart Lung. 1994 Jul-Aug;23(4):285-99. Heart Lung. 1994. PMID: 7960854 Review.
-
Physical examination of venous pressure: a critical review.Am Heart J. 1998 Jul;136(1):10-8. doi: 10.1016/s0002-8703(98)70175-9. Am Heart J. 1998. PMID: 9665212 Review.
Cited by
-
Point-of-Care Ultrasonography and Worsening of Renal Function in Acute Heart Failure: A Cohort Study.Can J Kidney Health Dis. 2025 Jul 29;12:20543581251328069. doi: 10.1177/20543581251328069. eCollection 2025. Can J Kidney Health Dis. 2025. PMID: 40756447 Free PMC article.
-
Point-of-Care Ultrasound for Jugular Venous Pressure Assessment: Live and Online Learning Compared.Cureus. 2017 Jun 8;9(6):e1324. doi: 10.7759/cureus.1324. Cureus. 2017. PMID: 28690957 Free PMC article.
-
A comparison of visual and quantitative assessment of left ventricular ejection fraction by cardiac magnetic resonance.Int J Cardiovasc Imaging. 2011 Apr;27(4):563-9. doi: 10.1007/s10554-010-9706-0. Epub 2010 Oct 1. Int J Cardiovasc Imaging. 2011. PMID: 20886372
-
Interobserver reliability of urine sediment interpretation.Clin J Am Soc Nephrol. 2009 Mar;4(3):567-71. doi: 10.2215/CJN.05331008. Epub 2009 Mar 4. Clin J Am Soc Nephrol. 2009. PMID: 19261816 Free PMC article.
-
Can peripheral venous pressure be interchangeable with central venous pressure in patients undergoing cardiac surgery?Intensive Care Med. 2004 Apr;30(4):627-32. doi: 10.1007/s00134-003-2052-0. Epub 2003 Nov 5. Intensive Care Med. 2004. PMID: 14600810 Clinical Trial.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical