Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2012 Dec;199(6):1220-5.
doi: 10.2214/AJR.11.8122.

80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL)and iomeprol (400 mg I/mL)

Affiliations
Comparative Study

80-kV pulmonary CT angiography with 40 mL of iodinated contrast material in lean patients: comparison of vascular enhancement with iodixanol (320 mg I/mL)and iomeprol (400 mg I/mL)

Lorenzo Faggioni et al. AJR Am J Roentgenol. 2012 Dec.

Abstract

Objective: The purpose of this article is to compare the vascular enhancement obtained with a low-kilovoltage pulmonary CT angiography (CTA) protocol in lean patients, using 40 mL of a moderate-concentration isoosmolar (iodixanol, 320 mg I/mL) and a high-concentration low-osmolar (iomeprol, 400 mg I/mL) iodinated contrast medium injected at the same iodine delivery rate.

Subjects and methods: Forty-two lean patients (31 men and 11 women; body mass index, ≤ 23 kg/m(2)) with suspected pulmonary embolism and non-small cell lung carcinoma underwent pulmonary CTA with a 64-MDCT scanner using a tube voltage of 80 kV. Twenty-three patients (54.8%) received 40 mL of iodixanol (320 mg I/mL) injected at a rate of 5 mL/s, and the remaining 19 patients (45.2%) were administered an equal volume of iomeprol (400 mg I/mL) at a flow rate of 4 mL/s. Intraarterial density was measured in the common pulmonary artery trunk, the main right and left pulmonary arteries, lobar arteries, and at the segmental level, for a total of 15 regions of interest per patient. Intravascular enhancement homogeneity from central to subsegmental level was also assessed visually using a semiquantitative score (1 = poor, 2 = good, and 3 = excellent).

Results: The overall vascular density of pulmonary arteries down to the segmental level was significantly higher with iodixanol (320 mg I/mL) than with iomeprol (400 mg I/mL) (p = 0.036). Enhancement homogeneity was good with both contrast agents, with no statistically significant difference between them (p = 0.8966).

Conclusion: In 80-kV pulmonary CTA of lean patients, higher intravascular enhancement can be achieved with 40 mL of iodixanol (320 mg I/mL) than with the same volume of iomeprol (400 mg I/mL), with good vessel conspicuity down to the subsegmental level.

PubMed Disclaimer

Comment in

Publication types

MeSH terms