Determination of three-dimensional imaging properties of a light microscope system. Partial confocal behavior in epifluorescence microscopy
- PMID: 2317554
- PMCID: PMC1280673
- DOI: 10.1016/S0006-3495(90)82534-0
Determination of three-dimensional imaging properties of a light microscope system. Partial confocal behavior in epifluorescence microscopy
Abstract
We have determined the three-dimensional image-forming properties of an epifluorescence microscope for use in obtaining very high resolution three-dimensional images of biological structures by image processing methods. Three-dimensional microscopic data is collected as a series of two-dimensional images recorded at different focal planes. Each of these images contains not only in-focus information from the region around the focal plane, but also out-of-focus contributions from the remainder of the specimen. Once the imaging properties of the microscope system are characterized, powerful image processing methods can be utilized to remove the out-of-focus information and to correct for image distortions. Although theoretical calculations for the behavior of an aberration-free microscope system are available, the properties of real lenses under the conditions used for biological observation are often far from an ideal. For this reason, we have directly determined the image-forming properties of an epifluorescence microscope under conditions relevant to biological observations. Through-focus series of a point object (fluorescently-coated microspheres) were recorded on a charge-coupled device image detector. From these images, the three-dimensional point spread function and its Fourier transform, the optical transfer function, were derived. There were significant differences between the experimental results and the theoretical models which have important implications for image processing. The discrepancies can be explained by imperfections of the microscope system, nonideal observation conditions, and partial confocal effects found to occur with epifluorescence illumination. Understanding the optical behavior of the microscope system has indicated how to optimize specimen preparation, data collection, and processing protocols to obtain significantly improved images.
Similar articles
-
High-definition mapping of neural activity using voltage-sensitive dyes.Methods. 2000 Aug;21(4):349-72. doi: 10.1006/meth.2000.1024. Methods. 2000. PMID: 10964579
-
Optimal model-based sensorless adaptive optics for epifluorescence microscopy.PLoS One. 2018 Mar 20;13(3):e0194523. doi: 10.1371/journal.pone.0194523. eCollection 2018. PLoS One. 2018. PMID: 29558510 Free PMC article.
-
Fluorescence microscopy in three dimensions.Methods Cell Biol. 1989;30:353-77. doi: 10.1016/s0091-679x(08)60986-3. Methods Cell Biol. 1989. PMID: 2494418 Review.
-
Thin-section ratiometric Ca2+ images obtained by optical sectioning of fura-2 loaded mast cells.J Cell Biol. 1992 Feb;116(3):745-59. doi: 10.1083/jcb.116.3.745. J Cell Biol. 1992. PMID: 1730775 Free PMC article.
-
Spinning-disk microscopy systems.Cold Spring Harb Protoc. 2010 Nov 1;2010(11):pdb.top88. doi: 10.1101/pdb.top88. Cold Spring Harb Protoc. 2010. PMID: 21041403 Review.
Cited by
-
Evidence for the organization of chromatin in megabase pair-sized loops arranged along a random walk path in the human G0/G1 interphase nucleus.J Cell Biol. 1995 Sep;130(6):1239-49. doi: 10.1083/jcb.130.6.1239. J Cell Biol. 1995. PMID: 7559748 Free PMC article.
-
HIV-1 Vpr interacts with the nuclear transport pathway to promote macrophage infection.Genes Dev. 1998 Jan 15;12(2):175-85. doi: 10.1101/gad.12.2.175. Genes Dev. 1998. PMID: 9436978 Free PMC article.
-
Highly multiplexed immunofluorescence imaging of human tissues and tumors using t-CyCIF and conventional optical microscopes.Elife. 2018 Jul 11;7:e31657. doi: 10.7554/eLife.31657. Elife. 2018. PMID: 29993362 Free PMC article.
-
Dynamics of a chemoattractant receptor in living neutrophils during chemotaxis.Mol Biol Cell. 1999 Apr;10(4):1163-78. doi: 10.1091/mbc.10.4.1163. Mol Biol Cell. 1999. PMID: 10198064 Free PMC article.
-
Tracking of single fluorescent particles in three dimensions: use of cylindrical optics to encode particle position.Biophys J. 1994 Sep;67(3):1291-300. doi: 10.1016/S0006-3495(94)80601-0. Biophys J. 1994. PMID: 7811944 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources