Randomized Controlled Trial
. 2013;35(2):216-21.
doi: 10.3109/0886022X.2012.743858. Epub 2012 Nov 23.

Can dialysis modality influence quality of life in chronic hemodialysis patients? Low-flux hemodialysis versus high-flux hemodiafiltration: a cross-over study

Affiliations
Free article
Randomized Controlled Trial

Can dialysis modality influence quality of life in chronic hemodialysis patients? Low-flux hemodialysis versus high-flux hemodiafiltration: a cross-over study

Konstantia Kantartzi et al. Ren Fail. 2013.
Free article

Abstract

Background: Hemodiafiltration with online preparation of the substitution [online high-flux hemodiafiltration (OHDF)] and hemodiafiltration with prepared bags of substitution (HDF) are important, recently widely used renal replacement therapies in patients with end-stage renal disease. However, there is little information on the comparative impacts of these modalities versus conventional low-flux hemodialysis (HD) on the quality of life (QoL) of HD patients. This study investigates the effect of dialysis modality on QoL in chronic HD patients.

Methods: In this prospective, randomized, cross-over, open label study, 24 patients were enrolled. Their age were 62 ± 13.34 years (mean ± SD), with the duration of dialysis of 31 ± 23.28 months (mean ± SD). Five of the patients were women. QoL was measured by the Short-Form Health Survey with 36 questions (SF-36) and subscale scores were calculated. Each patient received HD, OHDF, and HDF for 3 months, with the dialysis modality subsequently being altered. They completed the questionnaire of QoL at the end of each period.

Results: There were statistical significant differences in QoL for the total SF-36 [36.1 (26.7-45.7) and 40.7 (30.2-62.8)], for classic low-flux HD and high-flux hemodiafiltration, for bodily pain [45 (26.9-66.9) and 55 (35.6-87.5)], and for role limitations due to emotional functioning [0 (0-33.3) and 33.3 (0-100)], respectively. The scores did not differ significantly between the two types of hemodiafiltration.

Conclusions: Our study indicates that QoL differs significantly among patients receiving low-flux HD and high-flux hemodiafiltration, on total SF-36, bodily pain, and role limitations due to emotional functioning. Convective modalities may offer better QoL than diffusive HD.

PubMed Disclaimer