Thermodilution cardiac output values obtained by using a centrally placed introducer sheath and right atrial port of a pulmonary artery catheter
- PMID: 2318054
- DOI: 10.1097/00003246-199004000-00018
Thermodilution cardiac output values obtained by using a centrally placed introducer sheath and right atrial port of a pulmonary artery catheter
Abstract
Thermodilution cardiac output measurements obtained using a centrally placed introducer sheath were compared with thermodilution cardiac outputs obtained using the right atrial port of a balloon-tip, flow-directed pulmonary artery catheter in 15 patients with cardiac failure. Cardiac output values were obtained by manually injecting 10 ml of iced, D5W alternately through the introducer sheath and the right atrial port of the flow-directed catheter. Thirty cardiac output readings were obtained in the 15 patients. Cardiac outputs obtained using the right atrial port (CORA) did not differ significantly from cardiac outputs obtained using the introducer sheath (COSP) (5.3 +/- 0.2 vs. 5.2 +/- 0.2 L/min). The correlation between CORA and COSP was significant (r = .94, p less than .0001) and could be described by the formula CORA = 0.33 + 0.96 COSP. We conclude that when the right atrial port of a flow-directed catheter is nonfunctional, a thermodilution cardiac output obtained using a centrally placed introducer sheath offers a reliable alternative.
Similar articles
-
Effects of insertion depth and use of the sidearm of the introducer sheath of pulmonary artery catheters in cardiac output measurement.Crit Care Med. 1994 Jul;22(7):1132-5. doi: 10.1097/00003246-199407000-00014. Crit Care Med. 1994. PMID: 8026202 Clinical Trial.
-
Room-temperature thermodilution cardiac output. Central venous vs side port.Chest. 1993 Feb;103(2):339-41. doi: 10.1378/chest.103.2.339. Chest. 1993. PMID: 8432115 Clinical Trial.
-
The measurement of right ventricular ejection fraction by thermodilution. A comparison of values obtained using differing injectate ports.Anaesthesia. 1993 Apr;48(4):312-4. doi: 10.1111/j.1365-2044.1993.tb06950.x. Anaesthesia. 1993. PMID: 8494132
-
[Cardiac output determination with transpulmonary thermodilution. An alternative to pulmonary catheterization?].Anaesthesist. 1996 Nov;45(11):1045-50. doi: 10.1007/s001010050338. Anaesthesist. 1996. PMID: 9012299 Clinical Trial. German.
-
Simple method for measurement of cardiac output by thermodilution after cardiac operation.J Thorac Cardiovasc Surg. 1979 Nov;78(5):792-5. J Thorac Cardiovasc Surg. 1979. PMID: 385998
MeSH terms
LinkOut - more resources
Full Text Sources