Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
- PMID: 23184166
- DOI: 10.1590/s1806-83242012000600011
Bone density: comparative evaluation of Hounsfield units in multislice and cone-beam computed tomography
Abstract
The aim of this study was to evaluate the validity of the bone density value of potential implant sites in HU obtained by a specific cone-beam computed tomography (CBCT) device. In this study, the HU values obtained using a MSCT scanner were used as the gold standard. Twenty mandibles (40 potential implant sites) were scanned using an MSCT scanner (Somatom Sensation 40) and a CBCT scanner (i-CAT). The MSCT images were evaluated using the Syngo CT Workplace software and the CBCT images, using the XoranCat software. The images were evaluated twice by three oral radiologists, at 60 day intervals. The trabecular bone density of the same area was evaluated on both images. Intraclass coefficients (ICC) were calculated to examine the agreement between the examiners and between the two periods of evaluation. The bone density and area of the ROI were compared by the Student t test and Bland-Altman analysis. ICCs were excellent. The mean HU value obtained using CBCT (418.06) was higher than that obtained using MSCT (313.13), with a statistically significant difference (p < 0.0001). In addition, Bland-Altman analysis showed that the HU measures were not equivalent. In conclusion, the bone density in HU with CBCT images obtained using the device studied proved unreliable, since it was higher than that obtained using MSCT.
Similar articles
-
CBCT-based bone quality assessment: are Hounsfield units applicable?Dentomaxillofac Radiol. 2015;44(1):20140238. doi: 10.1259/dmfr.20140238. Dentomaxillofac Radiol. 2015. PMID: 25315442 Free PMC article. Review.
-
Bone quality evaluation at dental implant site using multislice CT, micro-CT, and cone beam CT.Clin Oral Implants Res. 2015;26(1):e1-7. doi: 10.1111/clr.12315. Epub 2013 Dec 11. Clin Oral Implants Res. 2015. PMID: 24325572
-
Quantification of bone quality using different cone beam computed tomography devices: Accuracy assessment for edentulous human mandibles.Eur J Oral Implantol. 2016;9(4):411-424. Eur J Oral Implantol. 2016. PMID: 27990508
-
Reliability of voxel gray values in cone beam computed tomography for preoperative implant planning assessment.Int J Oral Maxillofac Implants. 2012 Nov-Dec;27(6):1438-42. Int J Oral Maxillofac Implants. 2012. PMID: 23189294
-
Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review.Clin Oral Implants Res. 2018 Oct;29 Suppl 16:393-415. doi: 10.1111/clr.13142. Clin Oral Implants Res. 2018. PMID: 30328204
Cited by
-
CBCT-based bone quality assessment: are Hounsfield units applicable?Dentomaxillofac Radiol. 2015;44(1):20140238. doi: 10.1259/dmfr.20140238. Dentomaxillofac Radiol. 2015. PMID: 25315442 Free PMC article. Review.
-
Hounsfield unit for assessing bone mineral density distribution within lumbar vertebrae and its clinical values.Front Endocrinol (Lausanne). 2024 Jun 13;15:1398367. doi: 10.3389/fendo.2024.1398367. eCollection 2024. Front Endocrinol (Lausanne). 2024. PMID: 38938515 Free PMC article.
-
The Use of Intraoperative CT Hounsfield Unit Values for the Assessment of Bone Quality in Patients Undergoing Lumbar Interbody Fusion.Global Spine J. 2023 Oct;13(8):2218-2227. doi: 10.1177/21925682221078239. Epub 2022 Mar 1. Global Spine J. 2023. PMID: 35229676 Free PMC article.
-
Correlation between gray values of cone-beam computed tomograms and Hounsfield units of computed tomograms: A systematic review and meta-analysis.Imaging Sci Dent. 2022 Jun;52(2):133-140. doi: 10.5624/isd.20210274. Epub 2022 May 13. Imaging Sci Dent. 2022. PMID: 35799965 Free PMC article. Review.
-
Evaluating bone mineral density in osteoporotic vertebral compression fractures: the clinical utility of anterior column Hounsfield units.Front Endocrinol (Lausanne). 2025 Mar 20;16:1552780. doi: 10.3389/fendo.2025.1552780. eCollection 2025. Front Endocrinol (Lausanne). 2025. PMID: 40182640 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Miscellaneous