Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jan;6(1):202-9.
doi: 10.1007/s12194-012-0189-7. Epub 2012 Nov 27.

Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke

Affiliations

Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke

Hiroyuki Nagashima et al. Radiol Phys Technol. 2013 Jan.

Abstract

We developed a new computerized scheme for proper display of brain diffusion-weighted magnetic resonance images (DWIs) and apparent diffusion coefficient (ADC) maps based on density histogram analysis. In our scheme, DWI volumes and b0 image volumes of 44 cases were first created, and brain regions on DWI volumes were segmented. ADC map volumes were then derived from both volumes. The density histogram was determined from the brain regions on these volumes, and the voxel value corresponding to the maximum in the density histogram was determined for each volume. The display gray level for each of the two volumes was adjusted by setting the determined voxel value as window conditions. In a comparison between the existing manual method and our automated method, the variation in the gray levels was evaluated quantitatively. The variation in the average of the cross-correlation values determined for pairs of density histograms in each of the DWIs and ADC maps was 57.3 and 27.1 % with the existing method, respectively, and 7.7 and 2.7 % with our scheme, respectively, which indicated a more consistent display of images with our scheme. The performance of the two-alternative-forced-choice method for visual comparison of pairs of images in each of the DWIs and ADC maps adjusted by our scheme was judged to be better than those of the existing method by 75.1 % and 92.7 %, respectively. Our computerized scheme would be a promising technique for an accurate, prompt automated adjustment of display conditions in brain DWIs and ADC maps.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Stroke. 2009 May;40(5):1612-6 - PubMed
    1. Acad Radiol. 2000 Jul;7(7):530-9 - PubMed
    1. Magn Reson Med Sci. 2007;6(3):133-7 - PubMed
    1. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2006 Apr 20;62(4):555-64 - PubMed
    1. Stroke. 2003 Apr;34(4):1084-104 - PubMed

Publication types

LinkOut - more resources