Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2013 Feb;34(2):140-5.
doi: 10.1097/MNM.0b013e32835bd5da.

Comparison of criteria to truncate gastric emptying tests

Affiliations
Comparative Study

Comparison of criteria to truncate gastric emptying tests

Kenneth J Nichols et al. Nucl Med Commun. 2013 Feb.

Abstract

Purpose: Standardized scintigraphic gastric emptying (GE) protocols to detect gastroparesis (GP) require collecting data for 4 h. This investigation was undertaken to compare seven methods to reduce the duration of the test.

Materials and methods: This was a retrospective study of GE data collected using a standardized protocol at 0, 1, 2, 3, and 4 h for 602 patients being evaluated for GP. The reference standard was GP defined conventionally as percentage of gastric retention (GR) at 4 h (p4) of greater than 10%. For data up to 2 h the results were derived as follows: (a) confirming as being positive for GP if GR at 2 h was greater than 65%, negative for GP if GR at 2 h was less than 45%, and indeterminate otherwise; (b) by linear extrapolation; and (c) by monoexponential extrapolation. For data beyond 2 h, further evaluations were made and results were derived as follows: (a) confirming as being positive for GP if GR at 2.5 h was greater than 40%; (b) ascertainment of GR at 3 h; (c) by biphasic fit; and (d) by observation of maximum GR for normal patients at time points earlier than 4 h.

Results: Thirty percent of all patients had GP. Eighty percent were determinate by Method 1; for these patients sensitivity to detect GP was similar (P=0.11) for Methods 1-3 (69-79%). For data beyond 2 h, sensitivity of the seven methods ranged from 64 to 92%, and the sensitivity of every method was significantly lower than that of the reference standard (P<0.001).

Conclusion: Considering that sensitivity to detect GP was significantly reduced for data collection limited to 3 h or less, it is not advisable to truncate GE studies earlier than 4 h.

PubMed Disclaimer

Publication types

LinkOut - more resources