Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems
- PMID: 23189296
Fracture resistance of crowns cemented on titanium and zirconia implant abutments: a comparison of monolithic versus manually veneered all-ceramic systems
Abstract
Purpose: To evaluate the fracture resistance of all-ceramic crowns cemented on titanium and zirconia implant abutments.
Material and methods: Customized implant abutments for maxillary right central incisors made of titanium (Ti) and zirconia (Zr) (n=60, n=30 per group) were fabricated for an internal connection implant system. All-ceramic crowns were fabricated for their corresponding implant abutments using the following systems (n=10 per group): (1) monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate (MLD); (2) pressed lithium disilicate (PLD); (3) yttrium stabilized tetragonal zirconia polycrystal (YTZP). The frameworks of both PLD and YTZP systems were manually veneered with a fluorapatite-based ceramic. The crowns were adhesively cemented to their implant abutments and loaded to fracture in a universal testing machine (0.5 mm/minute). Data were analyzed using two-way analysis of variance (ANOVA) and Tukey's test (α=0.05).
Results: Both the abutment material (P=.0001) and the ceramic crown system (P=.028) significantly affected the results. Interaction terms were not significant (P=.598). Ti-MLD (558.5±35 N) showed the highest mean fracture resistance among all abutment-crown combinations (340.3±62-495.9±53 N) (P<.05). Both MLD and veneered ceramic systems in combination with Ti abutments (558.5±35-495.9±53 N) presented significantly higher values than with Zr abutments (392.9±55-340.3±62 N) (P<.05). MLD crown system showed significantly higher mean fracture resistance compared to manually veneered ones on both Ti and Zr abutments (P<.05). While Ti-MLD and Ti-PLD abutment-crown combinations failed only in the crowns without abutment fractures, Zr-YTZP combination failed exclusively in the abutment without crown fracture. Zr-MLD and Zr-PLD failed predominantly in both the abutment and the crown. Ti-YTZP showed only implant neck distortion.
Conclusions: The highest fracture resistance was obtained with titanium abutments restored with MLD crowns, but the failure type was more favorable with Ti-YTZP combination.
Similar articles
-
Marginal discrepancy of monolithic and veneered all-ceramic crowns on titanium and zirconia implant abutments before and after adhesive cementation: a scanning electron microscopy analysis.Int J Oral Maxillofac Implants. 2013 Mar-Apr;28(2):480-7. doi: 10.11607/jomi.2759. Int J Oral Maxillofac Implants. 2013. PMID: 23527350
-
Fracture Resistance of Titanium, Zirconia, and Ceramic-Reinforced Polyetheretherketone Implant Abutments Supporting CAD/CAM Monolithic Lithium Disilicate Ceramic Crowns After Aging.Int J Oral Maxillofac Implants. 2019 May/June;34(3):622–630. doi: 10.11607/jomi.7036. Epub 2019 Feb 4. Int J Oral Maxillofac Implants. 2019. PMID: 30716141
-
Mechanical stability of fully personalized, abutment-free zirconia implant crowns on a novel implant-crown interface.J Dent. 2022 Jun;121:104121. doi: 10.1016/j.jdent.2022.104121. Epub 2022 Apr 5. J Dent. 2022. PMID: 35395344
-
Zirconia in fixed implant prosthodontics.Clin Implant Dent Relat Res. 2012 Oct;14(5):633-45. doi: 10.1111/j.1708-8208.2010.00317.x. Epub 2010 Dec 22. Clin Implant Dent Relat Res. 2012. PMID: 21176095 Review.
-
Material and abutment selection for CAD/CAM implant-supported fixed dental prostheses in partially edentulous patients - A narrative review.Clin Oral Implants Res. 2024 Aug;35(8):984-999. doi: 10.1111/clr.14315. Epub 2024 Jun 12. Clin Oral Implants Res. 2024. PMID: 38864592 Review.
Cited by
-
Mechanical behavior of provisional implant prosthetic abutments.Med Oral Patol Oral Cir Bucal. 2015 Jan 1;20(1):e94-102. doi: 10.4317/medoral.19958. Med Oral Patol Oral Cir Bucal. 2015. PMID: 25129253 Free PMC article.
-
Evaluation of Milled Titanium versus Laser Sintered Co-Cr Abutments on the Marginal Misfit in Internal Implant-Abutment Connection.Materials (Basel). 2020 Oct 30;13(21):4873. doi: 10.3390/ma13214873. Materials (Basel). 2020. PMID: 33143092 Free PMC article.
-
Effects of Liner-Bonding of Implant-Supported Glass-Ceramic Crown to Zirconia Abutment on Bond Strength and Fracture Resistance.Materials (Basel). 2019 Aug 30;12(17):2798. doi: 10.3390/ma12172798. Materials (Basel). 2019. PMID: 31480271 Free PMC article.
-
[Stress in an implant-supported unitary fixed partial prosthesis with different materials in the first lower premolar through finite elements].Rev Cient Odontol (Lima). 2023 Mar 26;11(1):e140. doi: 10.21142/2523-2754-1101-2023-140. eCollection 2023 Jan-Mar. Rev Cient Odontol (Lima). 2023. PMID: 38288318 Free PMC article. Review. Spanish.
-
The Fracture Resistance of Additively Manufactured Monolithic Zirconia vs. Bi-Layered Alumina Toughened Zirconia Crowns When Cemented to Zirconia Abutments. Evaluating the Potential of 3D Printing of Ceramic Crowns: An In Vitro Study.Dent J (Basel). 2021 Oct 8;9(10):115. doi: 10.3390/dj9100115. Dent J (Basel). 2021. PMID: 34677177 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Miscellaneous