Quality control phantom for flat panel detector X-ray systems
Abstract
X-ray equipment should be routinely checked for optimal imaging performance and appropriate radiation dose. Recently, the use of diagnostic x-ray equipment with flat panel detectors (FPDs) has increased instead of image intensifier (II) and/or screen film systems. In addition, it is necessary to maintain the performance of FPD systems. Unfortunately, no simple quality control (QC) phantom is available for easy evaluation of FPD image performance. This manuscript suggests a novel simple and inexpensive QC phantom for radiography and fluoroscopy. The authors made a new QC phantom for FPD systems to evaluate the spatial resolution, low-contrast resolution, and dynamic range on single (one-shot) x-ray exposures. The phantom consists of three copper thicknesses (0.5, 1.5, and 3.0 mm), an aluminum stepwedge (0.1-2.7 mm), and piano wire of various diameters (0.08-0.5 mm). They also performed an initial check of the new phantom using a FPD system (fluoroscopic and radiographic images). The new phantom is simple and inexpensive to make. This simple phantom is very useful for QC of FPD systems because a visual evaluation of image performance in three thicknesses of copper (low, intermediate, and high attenuation) is readily available with a single exposure. This simple method for daily checking of FPD systems (radiography and fluoroscopy) using the phantom constitutes an easy way to routinely check image performance and will be useful for QC.
Similar articles
-
A Rotatable Quality Control Phantom for Evaluating the Performance of Flat Panel Detectors in Imaging Moving Objects.J Digit Imaging. 2016 Feb;29(1):38-42. doi: 10.1007/s10278-015-9816-2. J Digit Imaging. 2016. PMID: 26264731 Free PMC article.
-
[Canon's flat-panel detector].Igaku Butsuri. 2002;22(4):232-45. Igaku Butsuri. 2002. PMID: 12766269 Japanese.
-
Dual-energy cardiac imaging: an image quality and dose comparison for a flat-panel detector and x-ray image intensifier.Phys Med Biol. 2007 Jan 7;52(1):183-96. doi: 10.1088/0031-9155/52/1/012. Epub 2006 Dec 14. Phys Med Biol. 2007. PMID: 17183135
-
[Flat-panel detector technology -State-of-the-art and future prospects-].Igaku Butsuri. 2002;22(4):216-26. Igaku Butsuri. 2002. PMID: 12766267 Review. Japanese.
-
The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.Clin Radiol. 2008 Oct;63(10):1073-85. doi: 10.1016/j.crad.2008.06.002. Clin Radiol. 2008. PMID: 18774353 Review.
Cited by
-
A cross-sectional study of the radiation dose and image quality of X-ray equipment used in IVR.J Appl Clin Med Phys. 2016 Jul 8;17(4):391-401. doi: 10.1120/jacmp.v17i4.6231. J Appl Clin Med Phys. 2016. PMID: 27455503 Free PMC article.
-
Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging.Sensors (Basel). 2017 Mar 7;17(3):531. doi: 10.3390/s17030531. Sensors (Basel). 2017. PMID: 28272336 Free PMC article.
-
What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?Radiol Phys Technol. 2022 Jun;15(2):101-115. doi: 10.1007/s12194-022-00660-8. Epub 2022 May 24. Radiol Phys Technol. 2022. PMID: 35608759 Review.
-
Hybrid Operating Room System for the Treatment of Thoracic and Abdominal Aortic Aneurysms: Evaluation of the Radiation Dose Received by Patients.Diagnostics (Basel). 2020 Oct 19;10(10):846. doi: 10.3390/diagnostics10100846. Diagnostics (Basel). 2020. PMID: 33086733 Free PMC article.
-
Reducing the Breast Cancer Risk and Radiation Dose of Radiography for Scoliosis in Children: A Phantom Study.Diagnostics (Basel). 2020 Sep 25;10(10):753. doi: 10.3390/diagnostics10100753. Diagnostics (Basel). 2020. PMID: 32993028 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources