. 2013 Feb;65(1):1-6.
doi: 10.1016/j.yrtph.2012.11.003. Epub 2012 Nov 27.

Assessing the risk of Legionnaires' disease: the inhalation exposure model and the estimated risk in residential bathrooms

Affiliations

Assessing the risk of Legionnaires' disease: the inhalation exposure model and the estimated risk in residential bathrooms

Kenichi Azuma et al. Regul Toxicol Pharmacol. 2013 Feb.

Abstract

Legionella are widely found in the built environment. Patients with Legionnaires' disease have been increasing in Japan; however, health risks from Legionella bacteria in the environment are not appropriately assessed. We performed a quantitative health risk assessment modeled on residential bathrooms in the Adachi outbreak area and estimated risk levels. The estimated risks in the Adachi outbreak approximately corresponded to the risk levels exponentially extrapolated into lower levels on the basis of infection and mortality rates calculated from actual outbreaks, suggesting that the model of Legionnaires' disease in residential bathrooms was adequate to predict disease risk for the evaluated outbreaks. Based on this model, the infection and mortality risk levels per year in 10 CFU/100 ml (100 CFU/L) of the Japanese water quality guideline value were approximately 10(-2) and 10(-5), respectively. However, acceptable risk levels of infection and mortality from Legionnaires' disease should be adjusted to approximately 10(-4) and 10(-7), respectively, per year. Therefore, a reference value of 0.1 CFU/100 ml (1 CFU/L) as a water quality guideline for Legionella bacteria is recommended. This value is occasionally less than the actual detection limit. Legionella levels in water system should be maintained as low as reasonably achievable (<1 CFU/L).