Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy
- PMID: 23199515
- DOI: 10.1016/j.jacc.2012.09.035
Reproducibility of echocardiographic techniques for sequential assessment of left ventricular ejection fraction and volumes: application to patients undergoing cancer chemotherapy
Abstract
Objectives: The aim of this study was to identify the best echocardiographic method for sequential quantification of left ventricular (LV) ejection fraction (EF) and volumes in patients undergoing cancer chemotherapy.
Background: Decisions regarding cancer therapy are based on temporal changes of EF. However the method for EF measurement with the lowest temporal variability is unknown.
Methods: We selected patients in whom stable function in the face of chemotherapy for breast cancer was defined by stability of global longitudinal strain (GLS) at up to 5 time points (baseline, 3, 6, 9, and 12 months). In this way, changes in EF were considered to reflect temporal variability of measurements rather than cardiotoxicity. A comprehensive echocardiogram consisting of 2-dimensional (2D) and 3-dimensional (3D) acquisitions with and without contrast administration was performed at each time point. Stable LV function was defined as normal GLS (≤-16.0%) at each examination. The EF and volumes were measured with 2D-biplane Simpson's method, 2D-triplane, and 3-dimensional echocardiography (3DE) by 2 investigators blinded to any clinical data. Inter-, intra-, and test-retest variability were assessed in a subgroup. Variability was assessed by analysis of variance and compared with Levene's or t test.
Results: Among 56 patients (all female, 54 ± 13 years of age), noncontrast 3D EF, end-diastolic volume, and end-systolic volume had significantly lower temporal variability than all other methods. Contrast only decreased the temporal variability of LV end-diastolic volume measurements by the 2D biplane method. Our data suggest that a temporal variability in EF of 0.06 might occur with noncontrast 3DE due to physiological differences and measurement variability, whereas this might be >0.10 with 2D methods. Overall, 3DE also had the best intra- and inter-observer as well as test-retest variability.
Conclusions: Noncontrast 3DE was the most reproducible technique for LVEF and LV volume measurements over 1 year of follow-up.
Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Comment in
-
Is echocardiography reliable for monitoring the adverse cardiac effects of chemotherapy?J Am Coll Cardiol. 2013 Jan 8;61(1):85-7. doi: 10.1016/j.jacc.2012.10.006. Epub 2012 Nov 28. J Am Coll Cardiol. 2013. PMID: 23199517 No abstract available.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Miscellaneous