Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2013 Jun;94(6):1161-70.
doi: 10.1016/j.apmr.2012.11.030. Epub 2012 Nov 29.

Validity of pedometers in people with physical disabilities: a systematic review

Affiliations
Meta-Analysis

Validity of pedometers in people with physical disabilities: a systematic review

Amanda Kenyon et al. Arch Phys Med Rehabil. 2013 Jun.

Abstract

Objective: To review the literature for the criterion validity of pedometers for use in child and adult populations with physical disabilities.

Data sources: Academic Search Premier, ERIC, SPORTDiscus, MEDLINE, AMED, Scopus, CINAHL, Web of Science, and EMBASE databases, searched from inception to September 7, 2011.

Study selection: Studies were included if they were peer-reviewed articles, included populations with physical disabilities, and reported primary data for pedometer validity in comparison with direct observation. A consensus approach was used to apply the inclusion and exclusion criteria. Of the 163 articles identified in the database searches (excluding duplicates), 7 studies met the inclusion criteria.

Data extraction: The quality of the studies was assessed independently by 2 reviewers, using a purpose-designed appraisal tool, with a consensus approach used to settle disagreement. A single reviewer extracted data relating to sample size, participant characteristics, pedometer model, main variables tested, duration of tests, and method of direct observation.

Data synthesis: The methodologic quality of the studies was generally high; however, there was a wide variation of population and methodology between studies. The correlation between pedometer step counts and directly observed step counts was moderate to excellent (intraclass correlation coefficient, .52-.87), and percent errors ranged from 0.5% to 24.7%. Secondary variables reported included the effect of speed of movement, pedometer placement, comparison of pedometer makes/models, and test-retest reliability.

Conclusions: Available evidence suggests that pedometers are valid for use in clinical and research settings in people with physical disabilities. Further research examining the validity of pedometers in less heterogeneous populations of people with disabilities is warranted to determine validity for specific disability populations and to determine optimal pedometer placement.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources