A clinical evaluation of the Camino subdural screw and ventricular monitoring kits
- PMID: 2320210
- DOI: 10.1097/00006123-199003000-00007
A clinical evaluation of the Camino subdural screw and ventricular monitoring kits
Abstract
The aim of this study was to compare readings of intracranial pressure from a ventricular catheter with those obtained from a Camino catheter-tipped transducer. The Camino transducer was evaluated in two ways: firstly, when it was inserted by a subdural screw, and secondly, when it was inserted into a ventricular catheter using a ventricular monitoring kit. Data were recorded for 376 hours for the subdural screw method and for 486 hours for the ventricular monitoring kit. Average pressure readings were calculated every 5 minutes (10 half-minute values), and regression analysis was performed. For the subdural screw method, the correlation coefficient was 0.945 (gradient, 1.04; intercept, -5.51. The results from the ventricular monitoring kit showed that the correlation coefficient was 0.901 (gradient, 0.93; intercept, -0.92. The correlation between recordings of ventricular fluid pressure and the Camino recordings obtained from both subdural screw insertions and ventricular monitoring kits was good, with the subdural screw method proving more accurate and reliable in clinical use.
Similar articles
-
Clinical evaluation of two methods of subdural pressure monitoring.J Neurosurg. 1985 Oct;63(4):578-82. doi: 10.3171/jns.1985.63.4.0578. J Neurosurg. 1985. PMID: 4032022
-
Clinical evaluation of the Codman microsensor intracranial pressure monitoring system.Acta Neurochir Suppl. 1998;71:44-6. doi: 10.1007/978-3-7091-6475-4_14. Acta Neurochir Suppl. 1998. PMID: 9779140
-
An evaluation of the camino ventricular bolt system in clinical practice.Neurosurgery. 1993 Nov;33(5):866-8. doi: 10.1227/00006123-199311000-00013. Neurosurgery. 1993. PMID: 8264885
-
The Brain Trauma Foundation. The American Association of Neurological Surgeons. The Joint Section on Neurotrauma and Critical Care. Recommendations for intracranial pressure monitoring technology.J Neurotrauma. 2000 Jun-Jul;17(6-7):497-506. doi: 10.1089/neu.2000.17.497. J Neurotrauma. 2000. PMID: 10937892 Review.
-
Intracranial pressure monitoring techniques.New Horiz. 1995 Aug;3(3):395-9. New Horiz. 1995. PMID: 7496747 Review.
Cited by
-
Complications of brain tissue pressure monitoring with a fiberoptic device.Neurosurg Rev. 1998;21(4):254-9. doi: 10.1007/BF01105781. Neurosurg Rev. 1998. PMID: 10068186
-
Cerebral blood flow and metabolism in children with severe head injury. Part 1: Relation to age, Glasgow coma score, outcome, intracranial pressure, and time after injury.J Neurol Neurosurg Psychiatry. 1995 Feb;58(2):145-52. doi: 10.1136/jnnp.58.2.145. J Neurol Neurosurg Psychiatry. 1995. PMID: 7876842 Free PMC article.
-
Advances in Intracranial Pressure Monitoring and Its Significance in Managing Traumatic Brain Injury.Int J Mol Sci. 2015 Dec 4;16(12):28979-97. doi: 10.3390/ijms161226146. Int J Mol Sci. 2015. PMID: 26690122 Free PMC article. Review.
-
Accuracy of intracranial pressure monitoring: systematic review and meta-analysis.Crit Care. 2015 Dec 2;19:420. doi: 10.1186/s13054-015-1137-9. Crit Care. 2015. PMID: 26627204 Free PMC article.
-
Subdural intracranial pressure monitoring in craniosynostosis: its role in surgical management.Childs Nerv Syst. 1995 May;11(5):269-75. doi: 10.1007/BF00301758. Childs Nerv Syst. 1995. PMID: 7648567
MeSH terms
LinkOut - more resources
Full Text Sources