ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology
- PMID: 23218172
- DOI: 10.1016/j.icrp.2012.10.001
ICRP publication 121: radiological protection in paediatric diagnostic and interventional radiology
Erratum in
-
Corrigendum.Ann ICRP. 2020 Oct 5:146645320966413. doi: 10.1177/0146645320966413. Online ahead of print. Ann ICRP. 2020. PMID: 33455433 No abstract available.
-
CORRIGENDUM.Ann ICRP. 2021 Mar 25:1466453211000254. doi: 10.1177/01466453211000254. Online ahead of print. Ann ICRP. 2021. PMID: 33764810 No abstract available.
Abstract
Paediatric patients have a higher average risk of developing cancer compared with adults receiving the same dose. The longer life expectancy in children allows more time for any harmful effects of radiation to manifest, and developing organs and tissues are more sensitive to the effects of radiation. This publication aims to provide guiding principles of radiological protection for referring clinicians and clinical staff performing diagnostic imaging and interventional procedures for paediatric patients. It begins with a brief description of the basic concepts of radiological protection, followed by the general aspects of radiological protection, including principles of justification and optimisation. Guidelines and suggestions for radiological protection in specific modalities - radiography and fluoroscopy, interventional radiology, and computed tomography - are subsequently covered in depth. The report concludes with a summary and recommendations. The importance of rigorous justification of radiological procedures is emphasised for every procedure involving ionising radiation, and the use of imaging modalities that are non-ionising should always be considered. The basic aim of optimisation of radiological protection is to adjust imaging parameters and institute protective measures such that the required image is obtained with the lowest possible dose of radiation, and that net benefit is maximised to maintain sufficient quality for diagnostic interpretation. Special consideration should be given to the availability of dose reduction measures when purchasing new imaging equipment for paediatric use. One of the unique aspects of paediatric imaging is with regards to the wide range in patient size (and weight), therefore requiring special attention to optimisation and modification of equipment, technique, and imaging parameters. Examples of good radiographic and fluoroscopic technique include attention to patient positioning, field size and adequate collimation, use of protective shielding, optimisation of exposure factors, use of pulsed fluoroscopy, limiting fluoroscopy time, etc. Major paediatric interventional procedures should be performed by experienced paediatric interventional operators, and a second, specific level of training in radiological protection is desirable (in some countries, this is mandatory). For computed tomography, dose reduction should be optimised by the adjustment of scan parameters (such as mA, kVp, and pitch) according to patient weight or age, region scanned, and study indication (e.g. images with greater noise should be accepted if they are of sufficient diagnostic quality). Other strategies include restricting multiphase examination protocols, avoiding overlapping of scan regions, and only scanning the area in question. Up-to-date dose reduction technology such as tube current modulation, organ-based dose modulation, auto kV technology, and iterative reconstruction should be utilised when appropriate. It is anticipated that this publication will assist institutions in encouraging the standardisation of procedures, and that it may help increase awareness and ultimately improve practices for the benefit of patients.
Copyright © 2012. Published by Elsevier Ltd.
Similar articles
-
Radiological protection in paediatric computed tomography.Ann ICRP. 2012 Oct-Dec;41(3-4):170-8. doi: 10.1016/j.icrp.2012.06.017. Epub 2012 Sep 12. Ann ICRP. 2012. PMID: 23089016
-
ICRP PUBLICATION 120: Radiological protection in cardiology.Ann ICRP. 2013 Feb;42(1):1-125. doi: 10.1016/j.icrp.2012.09.001. Ann ICRP. 2013. PMID: 23141687 Review.
-
ICRP special radiation protection issues in interventional radiology, digital and cardiac imaging.Radiat Prot Dosimetry. 2005;117(1-3):13-7. doi: 10.1093/rpd/nci702. Epub 2006 Feb 3. Radiat Prot Dosimetry. 2005. PMID: 16461540
-
Pediatric interventional radiology and dose-reduction techniques.Semin Ultrasound CT MR. 2014 Aug;35(4):409-14. doi: 10.1053/j.sult.2014.05.007. Epub 2014 May 28. Semin Ultrasound CT MR. 2014. PMID: 25129217 Review.
-
ICRP Publication 117. Radiological protection in fluoroscopically guided procedures performed outside the imaging department.Ann ICRP. 2010 Dec;40(6):1-102. doi: 10.1016/j.icrp.2012.03.001. Ann ICRP. 2010. PMID: 22732420
Cited by
-
The Use of Intraoperative Radiography for Osteotomy Planning in Craniosynostosis Posterior Cranial Vault Distractor Application, Technique Description.Eplasty. 2020 Jul 6;20:e8. eCollection 2020. Eplasty. 2020. PMID: 32704341 Free PMC article. Review.
-
Genetic Analysis of T Cell Lymphomas in Carbon Ion-Irradiated Mice Reveals Frequent Interstitial Chromosome Deletions: Implications for Second Cancer Induction in Normal Tissues during Carbon Ion Radiotherapy.PLoS One. 2015 Jun 30;10(6):e0130666. doi: 10.1371/journal.pone.0130666. eCollection 2015. PLoS One. 2015. PMID: 26125582 Free PMC article.
-
Estimation of radiation exposure of children undergoing superselective intra-arterial chemotherapy for retinoblastoma treatment: assessment of local diagnostic reference levels as a function of age, sex, and interventional success.Neuroradiology. 2021 Mar;63(3):391-398. doi: 10.1007/s00234-020-02540-7. Epub 2020 Aug 29. Neuroradiology. 2021. PMID: 32862237 Free PMC article.
-
Pediatric Exposures to Ionizing Radiation: Carcinogenic Considerations.Int J Environ Res Public Health. 2016 Oct 28;13(11):1057. doi: 10.3390/ijerph13111057. Int J Environ Res Public Health. 2016. PMID: 27801855 Free PMC article. Review.
-
Eye lens radiation exposure in paediatric interventional treatment of retinoblastoma.Sci Rep. 2019 Dec 27;9(1):20113. doi: 10.1038/s41598-019-56623-4. Sci Rep. 2019. PMID: 31882988 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources