Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1990 Apr;49(4):556-63; discussion 563-4.
doi: 10.1016/0003-4975(90)90301-l.

Retrograde coronary sinus cardioplegia for aortic valve operations: a clinical report on 500 patients

Affiliations

Retrograde coronary sinus cardioplegia for aortic valve operations: a clinical report on 500 patients

P Menasché et al. Ann Thorac Surg. 1990 Apr.

Abstract

Retrograde delivery of cardioplegic solutions has recently been the subject of renewed interest, but the reliability of this technique has not been assessed in large clinical series. From 1980 to 1989, we used retrograde coronary sinus perfusion as the exclusive means of cardioplegia delivery in 500 consecutive patients undergoing aortic valve replacement, either isolated (359 patients) or combined with another valve or coronary procedure (141 patients). The coronary sinus was always cannulated under direct vision after bicaval cannulation with snaring. Cold crystalloid cardioplegia was delivered retrogradely at an average flow rate of 100 mL/min in conjunction with topical and systemic (25 degrees C) hypothermia. The mean cross-clamp time was 83 +/- 23 minutes (+/- the standard deviation). There were 31 hospital deaths (6.2%), 20 of which were cardiac related. Transient hemodynamic instability (defined as a need for inotropic agents for less than 24 hours postoperatively) occurred in 16 patients (3.2%), whereas a true low-output syndrome developed in 60 patients (12%). The incidence of clinically significant supraventricular arrhythmias and of permanent conduction defects was 7.4% and 1.2%, respectively. There were three nonfatal coronary venous injuries during our early experience. We conclude that coronary sinus perfusion is a safe and effective means of delivering cardioplegia in aortic valve operations. While providing a degree of myocardial protection similar to that reported with anterograde cardioplegia, the coronary sinus technique offers distinct advantages, in particular, the avoidance of perfusion-related coronary artery complications and the opportunity to repeat cardioplegia administration without interrupting the procedure.(ABSTRACT TRUNCATED AT 250 WORDS)

PubMed Disclaimer