Screw in the aorta: minimally invasive graft replacement for chronic aortic erosion by spinal instrument
- PMID: 23232300
- DOI: 10.5761/atcs.cr.12.01914
Screw in the aorta: minimally invasive graft replacement for chronic aortic erosion by spinal instrument
Abstract
Intra-and early post-operative aortic injury by pedicle screw is not a rare complication in orthopedic surgery, but aortic penetration by a screw head over a long time period is considered as an uncommon case. There are various surgical management options for thoracic aortic injury caused by malpositioned spinal instruments. We report a case of a patient who underwent minimally invasive graft replacement of the descending thoracic artery for pedicle screw penetration.