Endovascular treatment of cranial aneurysms with the pipeline flow-diverting stent: preliminary mid-term results
- PMID: 23233405
- DOI: 10.4261/1305-3825.DIR.6111-12.1
Endovascular treatment of cranial aneurysms with the pipeline flow-diverting stent: preliminary mid-term results
Abstract
Purpose: We aimed to present our initial experience with a new self-expanding flow diverter device designed for wide-neck aneurysm treatment, assess its safety for intracranial deployment and efficacy of occlusion at mid-term follow-up.
Materials and methods: Forty-five consecutive patients with difficult aneurysmal anatomy underwent an endovascular treatment. Fifty-five intracranial aneurysms were clipped using the Pipeline flow-diverting stent (ev3 Inc., Plymouth, Minnesota, USA) between November 2009 and December 2011. Data including antiplatelet therapy, technical issues, complications, and imaging findings were recorded during the follow-up period.
Results: Twenty-seven aneurysms were asymptomatic, 13 were symptomatic due to mass effect, seven were recurrent, six had subarachnoid hemorrhage, and two subjects presented with ischemia. There were 45 saccular, six fusiform-dissecting, and four blister aneurysms. The six-month control angiography was available in 34 subjects with an 85.3% (29/34 patients) complete occlusion rate. The overall occlusion rate according to the last angiography was 91.9% (34/37 patients). The following three major technical complications without clinical consequences were encountered: one distal wire fracture of the stent delivery system and two insufficient stent expansion. There was one fatal nonaneurysmal cerebellar hemorrhage. The overall mortality rate was 2.2% with no permanent morbidity.
Conclusion: The Pipeline flow-diverting stent represents an important advancement in endovascular therapy for cerebral aneurysms. Standard endovascular techniques are typically not suitable for these types of aneurysms. The device targets primary parent vessel reconstruction rather than endosaccular occlusion to achieve exclusion of the aneurysm and maintain a relatively high occlusion rate at six months.
Similar articles
-
Sole stenting with large cell stents for very small ruptured intracranial aneurysms.Interv Neuroradiol. 2014 Jan-Feb;20(1):45-53. doi: 10.15274/INR-2014-10007. Epub 2014 Feb 10. Interv Neuroradiol. 2014. PMID: 24556299 Free PMC article.
-
Pipeline flow-diverter stent for endovascular treatment of intracranial aneurysms: preliminary experience in 20 patients with 27 aneurysms.World Neurosurg. 2011 Jul-Aug;76(1-2):114-9. doi: 10.1016/j.wneu.2011.02.015. World Neurosurg. 2011. PMID: 21839962
-
The silk flow-diverting stent in the endovascular treatment of complex intracranial aneurysms: technical aspects and midterm results in 24 consecutive patients.Neurosurgery. 2012 Mar;70(3):617-23; discussion 623-4. doi: 10.1227/NEU.0b013e31823387d4. Neurosurgery. 2012. PMID: 21866071
-
Use of flow-diverting stents as salvage treatment following failed stent-assisted embolization of intracranial aneurysms.J Neurointerv Surg. 2016 Jul;8(7):692-5. doi: 10.1136/neurintsurg-2015-011672. Epub 2015 Jun 3. J Neurointerv Surg. 2016. PMID: 26041098 Review.
-
Endovascular treatment of blister aneurysms.Neurosurg Focus. 2017 Jun;42(6):E12. doi: 10.3171/2017.3.FOCUS1751. Neurosurg Focus. 2017. PMID: 28565977 Review.
Cited by
-
The combined treatment of stenting and surgery in a giant unruptured aneurysm of the middle cerebral artery.Surg Neurol Int. 2015 Apr 24;6:67. doi: 10.4103/2152-7806.155802. eCollection 2015. Surg Neurol Int. 2015. PMID: 25984382 Free PMC article.
-
The Combination of Stent and Antiplatelet Therapy May Be Responsible of Parenchymal Magnetic Susceptibility Artifacts after Endovascular Procedure.Tomography. 2021 Nov 13;7(4):792-800. doi: 10.3390/tomography7040066. Tomography. 2021. PMID: 34842852 Free PMC article.
-
Flow diverter retreatment for intracranial aneurysms: A meta-analysis of efficacy and feasibility.Interv Neuroradiol. 2024 Feb;30(1):37-42. doi: 10.1177/15910199221095972. Epub 2022 May 3. Interv Neuroradiol. 2024. PMID: 35505615 Free PMC article.
-
A novel virtual flow diverter implantation method with realistic deployment mechanics and validated force response.Int J Numer Method Biomed Eng. 2020 Jun;36(6):e3340. doi: 10.1002/cnm.3340. Epub 2020 Apr 17. Int J Numer Method Biomed Eng. 2020. PMID: 32279440 Free PMC article.
-
Visual outcomes with flow-diverter stents covering the ophthalmic artery for treatment of internal carotid artery aneurysms.AJNR Am J Neuroradiol. 2015 Feb;36(2):330-6. doi: 10.3174/ajnr.A4129. Epub 2014 Oct 22. AJNR Am J Neuroradiol. 2015. PMID: 25339649 Free PMC article.
MeSH terms
LinkOut - more resources
Full Text Sources
Medical