. 2013 Jun;51(6):1273-8.
doi: 10.1515/cclm-2012-0625.

Advancing haemostasis automation--successful implementation of robotic centrifugation and sample processing in a tertiary service hospital

Affiliations

Advancing haemostasis automation--successful implementation of robotic centrifugation and sample processing in a tertiary service hospital

Nazanin Sédille-Mostafaie et al. Clin Chem Lab Med. 2013 Jun.

Abstract

Background: Laboratories today face increasing pressure to automate operations due to increasing workloads and the need to reduce expenditure. Few studies to date have focussed on the laboratory automation of preanalytical coagulation specimen processing. In the present study, we examined whether a clinical chemistry automation protocol meets the preanalytical requirements for the analyses of coagulation.

Methods: During the implementation of laboratory automation, we began to operate a pre- and postanalytical automation system. The preanalytical unit processes blood specimens for chemistry, immunology and coagulation by automated specimen processing. As the production of platelet-poor plasma is highly dependent on optimal centrifugation, we examined specimen handling under different centrifugation conditions in order to produce optimal platelet deficient plasma specimens. To this end, manually processed models centrifuged at 1500 g for 5 and 20 min were compared to an automated centrifugation model at 3000 g for 7 min.

Results: For analytical assays that are performed frequently enough to be targets for full automation, Passing-Bablok regression analysis showed close agreement between different centrifugation methods, with a correlation coefficient between 0.98 and 0.99 and a bias between -5% and +6%. For seldom performed assays that do not mandate full automation, the Passing-Bablok regression analysis showed acceptable to poor agreement between different centrifugation methods.

Conclusions: A full automation solution is suitable and can be recommended for frequent haemostasis testing.