Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2013 Mar;8(2):173-80.
doi: 10.1007/s11739-012-0885-7. Epub 2012 Dec 16.

Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography

Affiliations
Observational Study

Verification of correct central venous catheter placement in the emergency department: comparison between ultrasonography and chest radiography

Maurizio Zanobetti et al. Intern Emerg Med. 2013 Mar.

Abstract

In 210 consecutive patients undergoing emergency central venous catheterization, we studied whether an ultrasonography examination performed at the bedside by an emergency physician can be an alternative method to chest X-ray study to verify the correct central venous catheter placement, and to identify mechanical complications. A prospective, blinded, observational study was performed, from January 2009 to December 2011, in the emergency department of a university-affiliated teaching hospital. Ultrasonography interpretation was completed during image acquisition; ultrasound scan was performed in 5 ± 3 min, whereas the time interval between chest radiograph request and its final interpretation was 65 ± 74 min p < 0.0001. We found a high concordance between the two diagnostic modalities in the identification of catheter position (Kappa = 82 %, p < 0.0001), and their ability to identify a possible wrong position showed a high correlation (Pearson's r = 0.76 %, p < 0.0001) with a sensitivity of 94 %, a specificity of 89 % for ultrasonography. Regarding the mechanical complications, three iatrogenic pneumothoraces occurred, all were correctly identified by ultrasonography and confirmed by chest radiography (sensitivity 100 %). Our study showed a high correlation between these two modalities to identify possible malpositioning of a catheter resulting from cannulation of central veins, and its complications. The less time required to perform ultrasonography allows earlier use of the catheter for the administration of acute therapies that can be life-saving for the critically ill patients.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Intensive Care Med. 2008 Feb;34(2):243-9 - PubMed
    1. Heart. 2009 Feb;95(2):164-70 - PubMed
    1. Cor Vasa. 1986;28(5):365-8 - PubMed
    1. Crit Care Med. 1997 Dec;25(12):2055-9 - PubMed
    1. Am J Med. 1999 Oct;107(4):340-3 - PubMed

Publication types

LinkOut - more resources